CBX ELECTRICAL CONNECTIONS
55
4
4.1.1 Ultra High Power Illuminator Models
Matrix 410 655-0x0 models require 24 Vdc. Power must be supplied to both the reader
(19-pin connector) and the Ultra High Power internal illuminator (M12 4-pin male connector).
This can be done from the CBX through the spring clamp terminal pins. Matrix 410™
receives power through the 25-pin cable connector while the illuminator receives power using
the CAB-LP-0x accessory cable connected directly between the illuminator and the CBX.
Connect the Brown/White wires to Vdc and Black/Blue wires to GND. Connect the cable
shield to Earth ground.
Figure 47 - Power Supply Connections for Matrix 410 655-0x0 Models
4.2 MAIN SERIAL INTERFACE
CAUTION
Do not connect to the Main Interface spring clamp terminals if using Host
Interface Modules (Fieldbus) with the CBX500.
The signals relative to the following serial interface types are available on the CBX spring
clamp terminal blocks.
The main serial interface type and its parameters (baud rate, data bits, etc.) can be
defined by the user via VisiSet™ software. The RS485 half duplex is automatically set
whenever MUX32 communication protocol is enabled. For more details refer to the
"Communication" folder in the VisiSet™ Help On Line.
Details regarding the connections and use of the interfaces are given in the next paragraphs.
From 24 Vdc Power Supply
V+
in
Earth
Ground
VGND
CAB-LP0x to Ultra High Power Illuminator
(brown)
(white)
(black)
(blue)
shield