MATRIX 410™ REFERENCE MANUAL
14
1
5. Press the "Fine Focusing" button to activate the Fine Focusing Tool.
The reader continuously acquires images and gives visual feedback on the focusing
quality in the Focusing Tool window.
Rotate the Focusing ring on the lens. The Current Focus Quality Bar (green) together
with the vertical optimal focus line (green) increase together until the optimal focus is
reached; the vertical optimal focus line stops.
Continue rotating the Focusing ring on the lens a little farther; the Current Focus
Quality Bar decreases (red) see below.
Rotate the Focusing ring in the opposite direction. The Current Focus Quality Bar (green)
increases towards the vertical optimal focus line (green) until the optimal focus is
reached; the Current Focus Quality Bar touches the vertical optimal focus line
(indicating the best focus).