RAPID CONFIGURATION
3
1
VisiSet™ Illuminator Management Procedure
1. Connect the reader to VisiSet™ as described in the Quick Reference Guide.
2. In the VisiSet™ Tools menu click the "Set Lighting System Part Number" item and select
the Illuminator being used from the list.
3. Click OK and wait until VisiSet™ resets. You can confirm by selecting the "Get Lighting
System Part Number" item from the same menu.
The above procedure must also be performed before any attempt to use the X-PRESS™
configuration on readers mounting the LT-005, LT-010 or LT-011 illuminators.
STEP 2 CONNECT THE SYSTEM
To connect the system in a Stand Alone configuration, you need the hardware indicated in
Figure 2. In this layout the data is transmitted to the Host on the main serial interface. Data
can also be transmitted on the RS232 auxiliary interface independently from the main
interface selection.
When One Shot or Phase Mode Operating mode is used, the reader is activated by an
External Trigger (photoelectric sensor) when the object enters its reading zone.
Figure 2 Matrix 410 in Stand Alone Layout
Figure 3 Matrix 410 655-0x0 Models in Stand Alone Layout
Matrix 410™ with
Ultra High Power
illuminator
1
2
Main Serial Interface (RS232 or RS485 Full-Duplex)
External Trigger (for One Shot or Phase Mode)
Host
PG6000
CBX
CAB-MSxx
CAB-LP-0x
Matrix 410™
Host
PG 6000
CBX
CAB-MSxx
I/O, AUX
1
2
Main Serial Interface (RS232 or RS485 Full-Duplex)
External Trigger (for One Shot or Phase Mode)
Vista de página 12