MATRIX 410™ REFERENCE MANUAL
108
7
7 READING FEATURES
7.1 OPTICAL ACCESSORY SELECTION
Referring to Figure 117 and the formula below, use the data in the following table to calculate
the FOV for your application.
Model
Lens
Viewing Angle
Horizontal
Viewing Angle
Vertical
Viewing Angle
Diagonal
Min Focus Distance
mm
Matrix 410
400-0x0
(SXGA)
LNS-1109 9 mm
48.5°
39.5°
60°
85
LNS-1112 12.5 mm
37°
30°
46.5°
85
LNS-1116 16 mm
28.5°
23°
36°
85
LNS-1125 25 mm
18.5°
15°
23.5°
135
LNS-1135 35 mm
13°
10,5°
16.5°
235
LNS-1150 50 mm
11.5°
500
Matrix 410
600-0x0
(UXGA)
LNS-1006 6 mm
59.5°
46.5°
71°
85
LNS-1109 9 mm
40.5°
31°
49.5°
85
LNS-1112 12.5 mm
31°
23.5°
38°
85
LNS-1116 16 mm
24°
18°
30°
85
LNS-1125 25 mm
15°
11.5°
19°
135
LNS-1135 35 mm
11°
8.5°
13.5°
235
LNS-1150 50 mm
7.5°
5.5°
9.5°
500
The viewing angle has a tolerance of 1° depending on the focus distance.
FOV
x
= 2 (d + 35 mm) tan (
x
/2)
where:
FOV
x
= horizontal, vertical or diagonal FOV
x
= horizontal, vertical or diagonal viewing angles.
d = focus distance (from window surface to code surface)
d
35 mm
FOV
plane
Figure 117 Reading Distance References