MATRIX 210™ PARAMETERS LIST
69
4
PARAMETER TYPE SEL STRING DATA
AIM DPM SETUP
Aperture Mode 1 1 <ESC> R L 0 = Automatic
1 = Custom
Aperture (mils) 0 <ESC> R M Range: 0 to 1000
Lighting 1 1 <ESC> R N 0 = 90
1 = D
2 = 30Q
3 = 30T
4 = 30S
5 = 45Q
Light Wavelength (nm) 1 1 <ESC> R O 0 = White
1 = 660
2 = 760
AIM DPM
Status 1 1 <ESC> R P 0 = Disabled
1 = Enabled
4.21 MISCELLANEOUS
PARAMETER TYPE SEL STRING DATA
READER INFORMATION
Reader Name 2 <ESC> Q A Length: 3 to 32
User Name 2 <ESC> Q O Length: 0 to 128
Line Name 2 <ESC> Q P Length: 0 to 128
IMAGE BUFFER
Status 1 1 <ESC> Q G 0 = Disabled
1 = Enabled
Saving Event
(One Shot, Continuous)
4 5 <ESC> Q H 1 = Complete Read
2 = Partial Read
4 = No Read
8 = Right Code
16 = Wrong Code
32 = Multiple Read
64 = Decoded But Not Collected
Saving Event
(Phase Mode, Code
Collection = Within An
Image)
4 5 <ESC> Q I 1 = Complete Read
2 = Partial Read
4 = No Read
8 = Right Code
16 = Wrong Code
32 = Multiple Read
64 = Decoded But Not Collected
Saving Event
(Phase Mode, Code
Collection = Within A
Phase)
4 2 <ESC> Q J 1 = Successful Decoding
2 = Decoding Failure
4 = Decoded But Not Collected
Max Number Of Images
In Buffer
0 <ESC> Q K Range: 1 to 5000
Image Subsampling 1 1 <ESC> Q L 0 = 1/1
1 = 1/4
2 = 1/16
3 = 1/64