MATRIX 210™ PARAMETERS LIST
35
4
PARAMETER TYPE SEL STRING DATA
Data Flow Control 1 1 <ESC> S w 0 = Disabled
1 = DAD Driver
2 = DPD Driver
Data Consistency 1 1 <ESC> S x 0 = Disabled
1 = Enabled
IP Addressing 1 1 <ESC> S y 0 = Static Assignment
1 = DHCP
2 = Remote Assignment
IP Address
(Static Addressing)
2 <ESC> S z Length: 1 to 15
Subnet Mask (Static
Addressing)
2 <ESC> S ! Length: 1 to 15
Gateway Address
(Static Addressing)
2 <ESC> S # Length: 1 to 15
Station Name 2 <ESC> S $ Length: 1 to 32
MODBUS TCP
Master Input Area Size 0 <ESC> S % Range: 8 to 144
Master Output Area
Size
0 <ESC> S & Range: 8 to 144
Data Flow Control 1 1 <ESC> S ( 0 = Disabled
1 = DAD Driver
2 = DPD Driver
Data Consistency 1 1 <ESC> S ) 0 = Disabled
1 = Enabled
IP Addressing 1 1 <ESC> S * 0 = Static Assignment
1 = DHCP
2 = Remote Assignment
IP Address
(Static Addressing)
2 <ESC> S + Length: 1 to 15
Subnet Mask (Static
Addressing)
2 <ESC> S / Length: 1 to 15
Gateway Address
(Static Addressing)
2 <ESC> S : Length: 1 to 15
Process Active Timeout
(ms)
0 <ESC> S - Range: 0 to 65535
Connection Timeout
(sec)
0 <ESC> S { Range: 0 to 65535
DIGITAL I/O CONDITIONING
Phase Echo 1 1 <ESC> S S 0 = Disabled
1 = Enabled
External Trigger Echo 1 1 <ESC> S T 0 = Disabled
1 = Enabled
Input 2 Echo 1 1 <ESC> S U 0 = Disabled
1 = Enabled
Output 1 1 1 <ESC> S V 0 = Disabled
1 = Enabled
Output 2 1 1 <ESC> S W 0 = Disabled
1 = Enabled