MATRIX 210™ HOST MODE PROGRAMMING
24
4
PARAMETER TYPE SEL STRING DATA
Image Rescaling 1 1 <ESC> k l #n 0 = None
1 = 2 x 2
2 = 4 x 4
Image Filter #n 1 1 <ESC> l #n 0 = None
1 = Erode
2 = Dilate
3 = Open
4 = Close
5 = Contrast Stretching
6 = Histogram Equalization
7 = Smoothing
8 = Sharpening
9 = Deblurring
10 = Black Enhancement
11 = White Enhancement
Image Filter Dimensions 1 1 <ESC> m #n 0 = 3x3
1 = 5x5
2 = 7x7
NOTE
Special characters <FE
H
> and <FD
H
> must be added after #n in the
programming string to indicate parameter Depth > 9. Refer to paragraph 3.2
for further details.
4.3 COMMUNICATION
25 PIN CONNECTOR MODELS
ETHERNET MODELS
PARAMETER TYPE SEL STRING DATA
MAIN PORT
Data TX 1 1 <ESC> B A 0 = Disabled
1 = Enabled
Serial Interface Type 1 1 <ESC> B B 0 = RS232
1 = RS485
Communication
Protocol
1 1 <ESC> B C 0 = None
1 = MUX32
2 = Siemens 3964
3 = Siemens RK512
Multidrop Address 0 <ESC> B D Range: 0 to 31
Baud Rate 1 1 <ESC> B E 0 = 2400
1 = 4800
2 = 9600
3 = 19200
4 = 38400
5 = 57600
6 = 115200