MATRIX 210™ PARAMETERS LIST
61
4
PARAMETER TYPE SEL STRING DATA
Aiming System Status 1 1 <ESC> N Z 0 = Disabled
1 = Enabled
LEDs Deactivation
Timeout (sec)
0 <ESC> N V Range: 0 to 300
Partial Read Treated
As
1 1 <ESC> N a 0 = No Read
1 = Complete Read
Multiple Read Treated
As
1 1 <ESC> N f 0 = No Read
1 = Complete Read
BEEPER
Status 1 1 <ESC> N T 0 = Disabled
1 = Enabled
Activation Events
(Match Code disabled)
3 4 <ESC> N D 0 = None
1 = Decoding
2 = Complete Read
4 = Partial Read
8 = No Read
16 = Multiple Read
Activation Events
(Match Code enabled)
3 4 <ESC> N E 0 = None
1 = Decoding
2 = Right Code
4 = Wrong Code
8 = No Read
Deactivation Timeout
(ms)
0 <ESC> N F Range: 1 to 1500
TEST MODE SETUP
Image Acquisition
Setting
0 <ESC> N b Range: 1 to 10
Number Of Samples 0 <ESC> N c Range: 5 to 1000
Test Mode Data TX 3 3 <ESC> N d 0 = None
1 = Auxiliary Port
2 = Main Port
4 = ID-NET
8 = Host Interface Port
Test Mode Exit Timeout
(sec)
0 <ESC> N e Range: 1 to 300
(0 = Disabled)
AUTOLEARNING SETUP (X-PRESS™)
Image Acquisition
Setting
0 <ESC> N J Range: 1 to 10
Calibration Mode 1 1 <ESC> N K 0 = Gain Only
1 = Exposure Time Only
2 = Exposure Time And Gain
Code Setting Mode 1 1 <ESC> N L 0 = General Purpose
1 = 2D Codes Only
2 = 1D Codes Only
3 = Direct Marking Only
4 = 1D And 2D Only
Add New Symbology 1 1 <ESC> N M 0 = Disabled
1 = Enabled
Store Memory 1 1 <ESC> N B 0 = Temporary
1 = Permanent
Store Match Code
Policy
1 1 <ESC> N z 0 = First Free Slot
1 = First Slot
Autolearning Timeout
(sec)
0 <ESC> N O Range: 1 to 300
(0 = Disabled)