Datalogic Controller SC6000 Manual do Utilizador Página 62

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 80
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 61
SC6000 HOST MODE PROGRAMMING
58
4
PARAMETER COMPLETE PATH SHC PT VALUE
Activation Event /IO/Out/Out1/Active 24 1 0 = None
1 = Complete Read
2 = Partial Read
3 = No Read
5 = Phase On
6 = Phase Off
8 = Multiple Read
Alternative Activation
Event
/IO/Out/Out1/Active1 - 1 0 = None
1 = Complete Read
2 = Partial Read
3 = No Read
5 = Phase On
6 = Phase Off
8 = Multiple Read
Deactivation Event /IO/Out/Out1/Deactive 25 1 0 = None
7 = Timeout
5 = Phase On
6 = Phase Off
Alternative Deactivation
Event
/IO/Out/Out1/Deactive1 - 1 0 = None
5 = Phase On
6 = Phase Off
Activate On Error /IO/Out/Out1
/ActiveDiagnoErr
- 1 0 = Disable
1 = Any Diagnostic
Error
2 = PS or Encoder Error
Deactivate When Errors
Recovered
/IO/Out/Out1
/DeactiveDiagnoNoErr
- 1 0 = Disable
1 = All Diagnostic
Errors Recovered
2 = PS and Encoder
Errors Recovered
Deactivation Timeout
(ms)
/IO/Out/Out1
/Timeout
26 0 Range: 40 to 15000
DIGITAL OUTPUT LINES / OUTPUT 3
Use /IO/Out/Out2/Use - 1 1 = Local
2 = Built-in EthernetIP
3 = Built-in Profinet
4 = Additional
EthernetIP
5 = Additional Profinet
6 = Profibus
Line State /IO/Out/Out2/Idle 27 1 0 = Normally Open
1 = Normally Closed
Activation Event /IO/Out/Out2/Active 28 1 0 = None
1 = Complete Read
2 = Partial Read
3 = No Read
5 = Phase On
6 = Phase Off
8 = Multiple Read
Vista de página 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 79 80

Comentários a estes Manuais

Sem comentários