PARAMETERS LIST
35
4
4.3 READING SYSTEM LAYOUT
PARAMETER COMPLETE PATH SHC PT VALUE
READING SYSTEM LAYOUT
Device Assignment /Layout/DevAssO 196 1 1 = Master RS232
(Type A)
2 = Master Lonworks and
RS232 (Type A)
4 = Controller Lon Old8k
5 = Controller Lon SC8000
Lon Noise Threshold /Layout
/NoiseLonThreshold
702 0 Range: 0 to 7
Number of Slaves
(Type A)
/Layout/NumSlSer 34 0 Range: 1 to 9
Number of LonWorks
Slaves
/Layout/NumSlOld8k - 0 Range: 1 to 14
Number of LonWorks
Slaves
/Layout/NumSlNet 36 0 Range: 1 to 31
Display Installer Info /Layout/ShowD/jointfilesconvert/266307/bg 38 1 0 = Disable
1 = Enable
Modify&Backup Lon
Slave Configuration
/Layout/Update 64 1 0 = Disable
1 = Enable
Enable Automatic
Replacement
(D.A.R.P.)
/Layout/EnableDARP - 1 0 = Disable
1 = Enable
Motor Delay (ms) /Layout/MotorDelay - 0 Range: 500 to 5000
LONWORKS SLAVES COMMON PARAMETERS (for backward compatibility)
CODE PARAMETERS
Code 3 of 9 /Layout/SlvPar/CodPar
/Cod39
140 1 0 = Disable
1 = Enable
Code 2 of 5
Interleaved
/Layout/SlvPar/CodPar
/Cod25
141 1 0 = Disable
1 = Enable
Code 2 of 5
Compressed
/Layout/SlvPar/CodPar
/Cod25Cmp
150 1 0 = Disable
1 = Enable
Code Codabar /Layout/SlvPar/CodPar
/CodBar
152 1 0 = Disable
1 = Enable
Code 93 /Layout/SlvPar/CodPar
/Cod93
151 1 0 = Disable
1 = Enable
Code 128 /Layout/SlvPar/CodPar
/Cod128
142 1 0 = Disable
1 = Enable
Code GS1-128
(ex EAN 128)
/Layout/SlvPar/CodPar
/CodEAN128
143 1 0 = Disable
1 = Enable
Code EAN 13 /Layout/SlvPar/CodPar
/EAN13
144 1 0 = Disable
1 = Enable
Code EAN 8 /Layout/SlvPar/CodPar
/EAN8
145 1 0 = Disable
1 = Enable
Code UPC A /Layout/SlvPar/CodPar
/UPCA
146 1 0 = Disable
1 = Enable
Code UPC E /Layout/SlvPar/CodPar
/UPCE
147 1 0 = Disable
1 = Enable
EAN/UPC
ADD ON 2
/Layout/SlvPar/CodPar
/AddOn2
148 1 0 = Disable
1 = Enable