2.5 NODE ID CONFIGURATION & MANAGEMENT
Only RS485-based RFID controllers can be connected to a Gateway’s Subnet
network and each must be assigned a unique Node ID value between 1 and 16.
When an RFID controller is connected to the Gateway’s Subnet network, the
Gateway will query the new controller to obtain certain configuration values
(specifically the Node ID number). If the Gateway does not detect a Node ID conflict,
it will “allow” the RFID controller onto the Subnet network.
By using the Cobalt HF
Configuration Tag that is
included with each RS485-
based Cobalt and HF-Series
RFID Controller, the Node ID
value can be dynamically
assigned by the Gateway or
can be manually assigned by
the user.
For the Gateway to
dynamically assign a Node
ID value to a controller, the
controller must first be
initialized with the Node ID
value of zero. This is the
equivalent of having no Node
ID assigned (note: all EMS
RS485-based controllers ship
with their Node ID value set
to 0).
When a controller (that is set
to Node ID 0) is connected to
the Subnet, it will not initially
be recognized by the
Gateway until the
Configuration Tag is placed
in the antenna’s RF field and
power to the controller is cycled. A few seconds after power is cycled to the controller
while the Configuration Tag is in RF range, the controller will display its new assigned
Node ID value in binary code from right to left using the five amber LEDs on the
controller.
When dynamically assigning a Node ID value for a new controller, the Gateway will
either assign the next available Node ID value or the value that the Gateway
recognizes as offline or “missing” – that is, a Node ID value that previously existed,
but has since disappeared from the network.
Because the Gateway stores a backup of each Subnet Node’s configuration, should
an RFID controller ever fail, a replacement controller can be installed quickly and
easily. The new controller will be automatically assigned the same Node ID value and
configuration as the replaced controller, provided the Configuration Tag is introduced
to the antenna field after startup.