GWY-01-DNT-01 MANUAL – REV. 02 CHAPTER 1:
GETTING STARTED
PAGE 15 OF 67
Figure 1-3: Subnet16 ThinNet Cable
7. For ThickNet Networks: Using a 5-pin, female, 7/8 - 16, ThickNet to
Bare Wire Leads cable (EMS P/N: CBL-1495-XX), connect the bare
wires to your power supply (SHIELD wire connected to GND). Attach the
female, ThickNet end to the 5-pin, male, ThickNet end on a Drop-T
connector (EMS P/N: CBL-1526).
8. For ThinNet Networks:
Using a 5-pin, female, M12, ThinNet to Bare
Wire Leads cable (EMS P/N: CBL-1494-XX), connect the bare wires to
your power supply (SHIELD wire connected to GND). Attach the female,
ThinNet end to the 5-pin, male, ThinNet end on a Drop-T connector
(EMS P/N: CBL-1486).
Figure 1-4: Subnet16 ThickNet Cable
9. Attach a DeviceNet-compatible data cable to the 5-pin, male M12
interface connector on the Gateway. Connect the other end of this cable
to your DeviceNet network.
10. Turn your power supply ON. The green PWR (power) LED on the
Gateway will illuminate. After the boot process is complete, the amber
DeviceNet LED will also glow to indicate that the Gateway is in
DeviceNet mode. The “DeviceNet” LED may appear green or red (solid
or flashing) depending on the status of the connection with your
DeviceNet network (see Table 2-2 in Section 2.2.1
for the behavior of the
Gateway’s DeviceNet LED).
OPTIONAL STEPS FOR ADDITIONAL CONFIGURATION
Steps 11 - 12 below are considered optional and only need to be completed by users
that wish to modify their Gateway’s internal configuration.
11. To modify the Gateway’s internal configuration, connect a USB cable to
the USB interface connector on the Gateway. Connect the other end of
this cable to a USB port on your host computer.
12. Download the Cobalt Dashboard Utility from www.ems-rfid.com
and
install the software on your host computer. Use the Dashboard Utility to
connect, via USB, to the Gateway. You will then be able to use the
Cobalt Dashboard Utility to configure the Gateway and send RFID
commands for testing purposes.
XX = length in Meters
GWY-01-DNT-01 DEVICENET FACTORY DEFAULTS
Node Address:
63
Data Rate:
125Kb (via 5-pin DeviceNet connection)