
Setup Procedure Using Programming Barcodes
21
2 TCP/IP ETHERNET INTERFACE TO HOST
2.1 FOR MATRIX 400 OR MATRIX 200 FAMILY READERS
For Matrix 400 or Matrix 200 readers
4
having software 5.60 or later, connected to either a
QL500 or a BM2x0 module (inside a CBX connection box), you can setup the Ethernet
communication with programming barcodes.
Ì$CBETHD$-}Î
Ethernet TCP/IP enabled
DHCP enabled
Using the X-PRESS™ interface setup functions described in the Quick Reference Guide,
correctly position the reader and read one of these barcodes with the Learn function
.
The reader can now communicate using Ethernet TCP/IP.
For reader configuration through VisiSet™ using Ethernet TCP/IP, follow one of the
procedures in par. 2.3.
Ì$CBETHN$-\Î
Ethernet TCP/IP enabled
DHCP disabled
(uses static IP Address parameters) *
The Factory Default static IP address parameter settings for all QL500 or BM2x0 modules
are:
IP Address = 172.24.24.1
Subnet Mask = 255.255.0.0
Gateway Address = 172.24.255.254
NOTE
For Matrix 400™ Ethernet models, Ethernet TCP/IP is enabled with the
above static IP address parameter settings by default. Therefore, it is not
necessary to read the DHCP disabled programming barcode for these
models.
4
Except Matrix 200™ UHD models.
Comentários a estes Manuais