Datalogic PowerScan D8530 Family Especificações Página 109

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 244
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 108
Enter Configuration
Exit and Save Configuration
Ì$+;Î
CODE SELECTION
Ì$-?Î
101
2/5 FAMILY
disable the family
ÌAC0QÎ
Read the desired family code
Read a check digit selection
Interleaved 2/5
ÌAC1TÎ
CHECK DIGIT TABLE
no check digit control
Normal 2/5 (5 Bars)
Ì12Î
ÌAC2WÎ
check digit control and transmission
Industrial 2/5 (IATA)
Ì23Î
ÌAC3ZÎ
check digit control without transmission
Matrix 2/5 (3 Bars)
Ì34Î
ÌAC4]Î
Read 4 numbers for the code length
where:
First 2 digits
= minimum code
length.
Second 2 digits = maximum code
length.
The pharmaceutical code below is part of
the 2/5 family but has no check digit or
code length selections.
The maximum code length is
99 characters.
The minimum code length must always
be less than or equal to the maximum.
Code CIP/HR
ÌAC5`Î
Examples:
0199 = variable from 1 to 99 digits in
the code.
1010 = 10 digit code length only.
French pharmaceutical code