Datalogic QuickScan QS6500BT Especificações

Consulte online ou descarregue Especificações para Leitores de códigos de barras Datalogic QuickScan QS6500BT. Datalogic QuickScan QS6500BT Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 388
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - Product Reference Guide

QuickScanTM iQD2100 General Purpose Corded HandheldLinear Imager Bar Code ReaderProduct Reference Guide

Página 2

8QuickScanTM QD2100NOTES

Página 3 - Table of Contents

IBM 46XX Interface90 QuickScanTM QD2100IBM 46XX Interface OptionsThis setting provides for an interface specific control mechanism..Options are:• Obey

Página 4

Product Reference Guide 91Chapter 10Wand Emulation InterfaceIntroductionThis chapter provides feature/settings configuration for the Wand Emulation in

Página 5

Wand Emulation Interface92 QuickScanTM QD2100Wand PolarityThis option specifies the polarity of the Wand output signal. Choices are:• Quiet zones and

Página 6

Wand Signal SpeedProduct Reference Guide 93Wand Signal SpeedThis feature specifies the speed of the Wand output signal per

Página 7

Wand Emulation Interface94 QuickScanTM QD2100Wand Label Symbology ConversionWhen this feature is enabled for the Wand Emulation interface, all bar cod

Página 8

Wand Transmit NoiseProduct Reference Guide 95Wand Transmit NoiseThis option specifies the leading/trailing noise for the Wa

Página 9

Wand Emulation Interface96 QuickScanTM QD2100NOTES

Página 10

Product Reference Guide 97Chapter 11Data EditingData Editing OverviewCAUTIONIt is not recommended to use these features with IBM inter-faces.When a ba

Página 11 - Introduction

Data Editing98 QuickScanTM QD2100Please Keep In Mind...• Modifying a message string is not a mandatory requirement. Data editing is sophisticated fea

Página 12 - References

Global Prefix/SuffixProduct Reference Guide 995. If less than the expected string of 20 characters are selected, scan the E

Página 13 - Technical Support

Product Reference Guide 1Chapter 1IntroductionAbout this GuideThis Product Reference Guide (PRG) is provided for users seeking advanced technical info

Página 14 - 4 QuickScan

Data Editing100 QuickScanTM QD2100Global AIM IDNOTEThis feature enables/disables addition of AIM IDs for all sym-bology types.AIM label identifiers (a

Página 15 - Getting Started

Global AIM IDProduct Reference Guide 101Global AIM ID — continuedENTER/EXIT PROGRAMMING MODEGlobal AIM ID = DisableGlobal A

Página 16 - Disconnecting at

Data Editing102 QuickScanTM QD2100GS1-128 AIM IDIf Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled inde-pendently. The AIM I

Página 17 - Programming

Label IDProduct Reference Guide 103Label IDA Label ID is a customizable code of up to three ASCII characters (each can be o

Página 18 - Configure Other Features

Data Editing104 QuickScanTM QD2100Table 17. Label ID Pre-loaded SetsSymbology USA Label ID set EU Label ID setASCIIcharacterHexvalueASCIIcharacterHexi

Página 19 - Software Version Transmission

Label IDProduct Reference Guide 105I2OF5 i 690000 N 4E0000IATA IA 494100 & 260000Industrial 2 of 5 W 570000 W 570000Int

Página 20 - 10 QuickScan

Data Editing106 QuickScanTM QD2100Label ID: Set Individually Per SymbologyTo configure a Label ID individually for a single symbology:1. Scan the ENTE

Página 21 - Interfaces

Label IDProduct Reference Guide 107Label ID — continuedTable 18STEP ACTION EXAMPLES1. Scan the ENTER/EXIT bar code (Scanner

Página 22 - Table 1. Available Interfaces

Data Editing108 QuickScanTM QD2100Label ID — continuedLabel ID ControlThis option controls whether a Label ID is disabled, or sent as a prefix or suff

Página 23

Label IDProduct Reference Guide 109Label ID — continuedLabel ID Symbology SelectionThis option selects the symbology for wh

Página 24

Introduction2 QuickScanTM QD2100Chapter 12, Symbologies defines options for all symbologies and provides the program-ming bar codes necessary for conf

Página 25 - Global Interface Features

Data Editing110 QuickScanTM QD2100Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Label ID i

Página 26 - USB Suspend Mode

Label IDProduct Reference Guide 111Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symb

Página 27 - General Features

Data Editing112 QuickScanTM QD2100Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Label ID i

Página 28 - 18 QuickScan

Label IDProduct Reference Guide 113Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symb

Página 29 - Label Gone Timeout

Data Editing114 QuickScanTM QD2100Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Label ID i

Página 30 - Label Gone Timeout — cont

Label IDProduct Reference Guide 115Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symb

Página 31 - LED and Beeper Indicators

Data Editing116 QuickScanTM QD2100Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Label ID i

Página 32 - Good Read: When to Indicate

Case ConversionProduct Reference Guide 117Case ConversionThis feature allows conversion of the case of all alphabetic chara

Página 33 - Good Read Beep Type

Data Editing118 QuickScanTM QD2100Character ConversionCharacter conversion is an eight byte configuration item. The eight bytes are 4 character pairs

Página 34 - Good Read Beep Length

Character ConversionProduct Reference Guide 119Character Conversion — continuedENTER/EXIT PROGRAMMING MODEConfigure Charact

Página 35

Technical SupportProduct Reference Guide 3Technical SupportDatalogic Website SupportThe Datalogic website (www.datalogic.co

Página 36 - Good Read Beep Volume

Data Editing120 QuickScanTM QD2100NOTES

Página 37 - Good Read LED Duration

Product Reference Guide 121Chapter 12SymbologiesIntroductionThe reader supports the following symbologies (bar code types). Options for each sym-bolog

Página 38 - 2 seconds

Symbologies122 QuickScanTM QD2100Standard Factory Settings for SymbologiesDefault settings are indicated at each feature/option with a green arrow. Al

Página 39 - Scanning Features

Coupon ControlProduct Reference Guide 123Coupon ControlThis feature is used to control the method of processing coupon labe

Página 40 - Scan Mode — continued

Symbologies124 QuickScanTM QD2100UPC-AThe following options apply to the UPC-A symbology.UPC-A Enable/DisableWhen disabled, the reader will not read U

Página 41 - Stand Mode Triggered Timeout

UPC-AProduct Reference Guide 125UPC-A — cont.Expand UPC-A to EAN-13Expands UPC-A data to the EAN-13 data format. Selecting

Página 42 - 32 QuickScan

Symbologies126 QuickScanTM QD2100UPC-A — cont.In-Store Minimum ReadsThis feature specifies the minimum number of consecutive times an in-store label m

Página 43 - Scanning Active Time

UPC-EProduct Reference Guide 127UPC-EThe following options apply to the UPC-E symbology.UPC-E Enable/DisableWhen disabled,

Página 44 - Scanning Active Time — cont

Symbologies128 QuickScanTM QD2100UPC-E — cont.Expand UPC-E to EAN-13Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes

Página 45 - Flash On Time

UPC-EProduct Reference Guide 129UPC-E — cont.UPC-E Number System Character TransmissionThis feature enables/disables transm

Página 46 - Flash On Time — cont

Introduction4 QuickScanTM QD2100NOTES

Página 47 - Flash Off Time

Symbologies130 QuickScanTM QD2100UPC-E — cont.UPC-E Minimum ReadsThis feature specifies the minimum number of consecutive times a UPC-E label must be

Página 48 - Flash Off Time — cont

GTIN FormattingProduct Reference Guide 131GTIN FormattingThis feature enables/disables the ability to convert UPC-E, UPC-A,

Página 49 - Stand Mode Sensitivity

Symbologies132 QuickScanTM QD2100EAN 13The following options apply to the EAN 13 (Jan 13) symbology.EAN 13 Enable/DisableWhen disabled, the reader wil

Página 50 - Green Spot Duration

EAN 13Product Reference Guide 133EAN 13 — cont.EAN-13 Flag 1 CharacterEnables/disables transmission of an EAN/JAN13 Flag1 c

Página 51 - RS-232 ONLY Interface

Symbologies134 QuickScanTM QD2100EAN-13 ISBN ConversionThis option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to I

Página 52 - Baud Rate — continued

EAN 13Product Reference Guide 135EAN 13 — cont.EAN 13 Minimum ReadsThis feature specifies the minimum number of consecutive

Página 53 - Data Bits

Symbologies136 QuickScanTM QD2100EAN 8The following options apply to the EAN 8 (Jan 8) symbology.EAN 8 Enable/DisableWhen disabled, the reader will no

Página 54 - Stop Bits

EAN 8Product Reference Guide 137EAN 8 — cont.Expand EAN 8 to EAN 13Enable this option to expand EAN 8/JAN 8 labels to EAN 1

Página 55

Symbologies138 QuickScanTM QD2100EAN 8 — cont.EAN 8 Minimum ReadsThis feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label

Página 56 - Handshaking Control

UPC/EAN Global SettingsProduct Reference Guide 139UPC/EAN Global SettingsThis section provides configuration settings for U

Página 57 - RS-232/USB-Com Interfaces

Product Reference Guide 5Chapter 2Getting StartedAbout the ImagerAdvancements in the LED technology used in this imager significantly improve the illu

Página 58 - Intercharacter Delay

Symbologies140 QuickScanTM QD2100UPC/EAN Global Settings — cont.UPC/EAN Decoding Level — cont.ENTER/EXIT PROGRAMMING MODEUPC/EAN Decoding Level = 1UPC

Página 59 - Intercharacter Delay — cont

UPC/EAN Global SettingsProduct Reference Guide 141UPC/EAN Global Settings — cont.UPC/EAN CorrelationWhen correlation is ena

Página 60 - Beep On Not on File

Symbologies142 QuickScanTM QD2100UPC/EAN Global Settings — cont.UPC/EAN Price Weight CheckThis feature enables/disables calculation and verification o

Página 61 - ACK NAK Options

UPC/EAN Global SettingsProduct Reference Guide 143UPC/EAN Global Settings — cont.UPC-A Minimum ReadsThis feature specifies

Página 62 - ACK Character

Symbologies144 QuickScanTM QD2100Add-OnsThe following features apply to optional add-ons.NOTEContact Customer Support for advanced programming of opti

Página 63 - ACK Character — cont

Add-OnsProduct Reference Guide 145Add-Ons — cont.Optional Add-ons — cont.ENTER/EXIT PROGRAMMING MODEOptional Add-Ons = Enab

Página 64 - NAK Character

Symbologies146 QuickScanTM QD2100Add-Ons — cont.Optional Add-On TimerThis option sets the time the reader will look for an add-on when an add-on fragm

Página 65 - NAK Character — cont

Add-OnsProduct Reference Guide 147Add-Ons — cont.Optional Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional Add-on Ti

Página 66 - ACK NAK Timeout Value

Symbologies148 QuickScanTM QD2100Add-Ons — cont.Optional Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional Add-on Timer = 180msOptional Add-on T

Página 67 - ACK NAK Timeout Value — cont

Add-OnsProduct Reference Guide 149Add-Ons — cont.Optional GS1-128 Add-On TimerThis option sets the timer expiration value t

Página 68 - ACK NAK Retry Count

Getting Started6 QuickScanTM QD2100Setting Up the ImagerFollow the steps provided in this section to connect and get your imager up and commu-nicating

Página 69 - ACK NAK Retry Count — cont

Symbologies150 QuickScanTM QD2100Add-Ons — cont.Optional GS1-128 Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional GS1-128 Add-On Timer = 60msOp

Página 70 - ACK NAK Error Handling

Add-OnsProduct Reference Guide 151Add-Ons — cont.Optional GS1-128 Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional G

Página 71 - Indicate Transmission Failure

Symbologies152 QuickScanTM QD2100Add-Ons — cont.P2 Add-Ons Minimum ReadsThis feature specifies the minimum number of times a P2 add-on must be read be

Página 72 - Disable Character

Add-OnsProduct Reference Guide 153Add-Ons — cont.P5 Add-Ons Minimum ReadsThis feature specifies the minimum number of times

Página 73 - Disable Character — cont

Symbologies154 QuickScanTM QD2100Add-Ons — cont.GS1-128 Add-Ons Minimum ReadsThis feature specifies the minimum number of times an GS1-128 add-on must

Página 74 - Enable Character

GS1 DataBarTM OmnidirectionalProduct Reference Guide 155GS1 DataBarTM OmnidirectionalThe following options apply to the GS1

Página 75 - Enable Character — cont

Symbologies156 QuickScanTM QD2100GS1 DataBarTM Omnidirectional — cont.GS1 DataBar Omnidirectional Minimum ReadsThis feature specifies the minimum numb

Página 76 - 66 QuickScan

GS1 DataBarTM ExpandedProduct Reference Guide 157GS1 DataBarTM ExpandedThe following options apply to the GS1 DataBar Expan

Página 77 - Keyboard Interface

Symbologies158 QuickScanTM QD2100GS1 DataBarTM Expanded — cont.GS1 DataBar Expanded Minimum ReadsThis feature specifies the minimum number of consecut

Página 78 - Country Mode

GS1 DataBarTM ExpandedProduct Reference Guide 159GS1 DataBarTM Expanded — cont.GS1 DataBar Expanded Length ControlThis feat

Página 79 - Country Mode — continued

Setting Up the ImagerProduct Reference Guide 7USB Connection — Connect the imager to a USB port on the terminal/PC using t

Página 80

Symbologies160 QuickScanTM QD2100GS1 DataBarTM Expanded — cont.GS1 DataBar Expanded Set Length 1This feature specifies one of the bar code lengths for

Página 81 - Caps Lock State

GS1 DataBarTM ExpandedProduct Reference Guide 161GS1 DataBarTM Expanded — cont.GS1 DataBar Expanded Set Length 1 — cont.ENT

Página 82 - Send Control Characters

Symbologies162 QuickScanTM QD2100GS1 DataBarTM Expanded — cont.GS1 DataBar Expanded Set Length 2This feature specifies one of the bar code lengths for

Página 83 - Wedge Quiet Interval

GS1 DataBarTM ExpandedProduct Reference Guide 163GS1 DataBarTM Expanded — cont.GS1 DataBar Expanded Set Length 2 — cont.ENT

Página 84 - Wedge Quiet Interval — cont

Symbologies164 QuickScanTM QD2100GS1 DataBarTM LimitedThe following options apply to the GS1 DataBar Limited (formerly RSS Limited) sym-bology.GS1 Dat

Página 85

GS1 DataBarTM LimitedProduct Reference Guide 165GS1 DataBarTM Limited — cont.GS1 DataBar Limited Minimum ReadsThis feature

Página 86

Symbologies166 QuickScanTM QD2100Code 39The following options apply to the Code 39 symbology.Code 39 Enable/DisableWhen disabled, the reader will not

Página 87 - Intercode Delay

Code 39Product Reference Guide 167Code 39 — cont.Code 39 Check Character CalculationEnable this option to enable/disable ca

Página 88 - Intercode Delay — cont

Symbologies168 QuickScanTM QD2100Code 39 — cont.Code 39 Check Character TransmissionEnable this option to transmit the check character along with Code

Página 89 - USB Keyboard Speed

Code 39Product Reference Guide 169Code 39 — cont.Code 39 Full ASCIIIn Code 39 decoding, this enables/disables the translati

Página 90 - 80 QuickScan

Getting Started8 QuickScanTM QD2100Using the Programming bar codesThis manual contains feature descriptions and bar codes which allow you to reconfigu

Página 91 - USB-OEM Interface

Symbologies170 QuickScanTM QD2100Code 39 — cont.Code 39 Quiet ZonesThis feature specifies the number of quiet zones for Code 39 labels. Quiet zones ar

Página 92 - USB-OEM Device Usage

Code 39Product Reference Guide 171Code 39 — cont.Code 39 Minimum ReadsThis feature specifies the minimum number of consecut

Página 93 - USB-OEM Interface Options

Symbologies172 QuickScanTM QD2100Code 39 — cont.Code 39 Decoding LevelDecoding Levels are used to configure a bar code symbology decoder to be very ag

Página 94 - 84 QuickScan

Code 39Product Reference Guide 173Code 39 — cont.Code 39 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECode 39 Decoding

Página 95 - IBM 46XX Interface

Symbologies174 QuickScanTM QD2100Code 39 — cont.Code 39 Length ControlThis feature specifies either variable length decoding or fixed length decoding

Página 96 - 46xx Number of Host Resets

Code 39Product Reference Guide 175Code 39 — cont.Code 39 Set Length 1This feature specifies one of the bar code lengths for

Página 97

Symbologies176 QuickScanTM QD2100Code 39 — cont.Code 39 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 39 Set Length 1 SettingMake a mista

Página 98 - 88 QuickScan

Code 39Product Reference Guide 177Code 39 — cont.Code 39 Set Length 2This feature specifies one of the bar code lengths for

Página 99 - Code 39 Format —

Symbologies178 QuickScanTM QD2100Code 39 — cont.Code 39 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 39Length 2 SettingMake a mistake? S

Página 100 - IBM 46XX Interface Options

Code 39Product Reference Guide 179Code 39 — cont.Code 39 Interdigit RatioThis feature specifies the ratio between an interc

Página 101 - Wand Emulation Interface

Resetting the Product Configuration to DefaultsProduct Reference Guide 9Software Version TransmissionThe software version o

Página 102 - Wand Polarity

Symbologies180 QuickScanTM QD2100Code 39 — cont.Code 39 Interdigit Ratio — cont.ENTER/EXIT PROGRAMMING MODECode 39 Interdigit Ratio = 6Code 39 Interdi

Página 103 - Wand Signal Speed

Code 39Product Reference Guide 181Code 39 — cont.Code 39 Character CorrelationWhen correlation is enabled, the bar code rea

Página 104 - Options are:

Symbologies182 QuickScanTM QD2100Code 39 StitchingThis option enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are pres

Página 105 - Wand Transmit Noise

Code 32 (Italian Pharmaceutical)Product Reference Guide 183Code 32 (Italian Pharmaceutical)The following options apply to t

Página 106 - 96 QuickScan

Symbologies184 QuickScanTM QD2100Code 32 (Italian Pharmaceutical) — cont.Code 32 Check Character TransmissionEnable this option to transmit the check

Página 107 - Data Editing

Code 39 CIP (French Pharmaceutical)Product Reference Guide 185Code 39 CIP (French Pharmaceutical)The following options appl

Página 108 - Global Prefix/Suffix

Symbologies186 QuickScanTM QD2100Code 128 — cont.Expand Code 128 to Code 39This feature enables/disables expansion of Code 128 labels to Code 39 labe

Página 109

Code 128Product Reference Guide 187Code 128 — cont.Code 128 Function Character TransmissionEnables/disables transmission of

Página 110 - Global AIM ID

Symbologies188 QuickScanTM QD2100Code 128 — cont.Code 128 Sub-Code Change Transmission Enables/disables the transmission of “Sub-Code exchange” charac

Página 111 - Global AIM ID — continued

Code 128Product Reference Guide 189Code 128 — cont.Code 128 Quiet ZonesThis feature specifies the number of quiet zones for

Página 112 - GS1-128 AIM ID

Datalogic ADC, Inc.959 Terry StreetEugene, OR 97402USATelephone: (541) 683-5700Fax: (541) 345-7140© 2008-2014 Datalogic ADC, Inc.An Unpublished Work -

Página 113 - Label ID

Getting Started10 QuickScanTM QD2100Resetting the Product Configuration to Defaults — cont.If you aren't sure what programming options are in you

Página 114 - 104 QuickScan

Symbologies190 QuickScanTM QD2100Code 128 — cont.Code 128 Minimum ReadsThis feature specifies the minimum number of consecutive times a Code 128 label

Página 115 -

Code 128Product Reference Guide 191Code 128 — cont.Code 128 Decoding LevelDecoding Levels are used to configure a bar code

Página 116

Symbologies192 QuickScanTM QD2100Code 128 — cont.Code 128 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECode 128 Decoding Level = 1Code 128 Decodin

Página 117 - Label ID — continued

Code 128Product Reference Guide 193Code 128 — cont.Code 128 Length ControlThis feature specifies either variable length dec

Página 118

Symbologies194 QuickScanTM QD2100Code 128 — cont.Code 128 Set Length 1This feature specifies one of the bar code lengths for Code 128 Length Control.

Página 119

Code 128Product Reference Guide 195Code 128 — cont.Code 128 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 128

Página 120

Symbologies196 QuickScanTM QD2100Code 128 — cont.Code 128 Set Length 2This feature specifies one of the bar code lengths for Code 128 Length Control.

Página 121

Code 128Product Reference Guide 197Code 128 — cont.Code 128 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 128

Página 122

Symbologies198 QuickScanTM QD2100Code 128 — cont.Code 128 Character CorrelationWhen correlation is enabled, the bar code reader will combine label dat

Página 123

Code 128Product Reference Guide 199Code 128 — cont.Code 128 StitchingThis option enables/disables stitching for Code 128 la

Página 124

Product Reference Guide 11Chapter 3InterfacesInterface SelectionEach reader model will support one of the following sets of host interfaces: General

Página 125

Symbologies200 QuickScanTM QD2100GS1-128The following options apply to the GS1-128 symbology. (Also known as USS-128, GTIN-128, UCC-128.)GS1-128 Enabl

Página 126

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 201Interleaved 2 of 5 (I 2 of 5)The following options apply to the I 2

Página 127 - Case Conversion

Symbologies202 QuickScanTM QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Check Character CalculationThis option enables/disables calculation and

Página 128 - Character Conversion

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 203Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Check Character Calcu

Página 129

Symbologies204 QuickScanTM QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Minimum ReadsThis feature specifies the minimum number of consecutive t

Página 130 - 120 QuickScan

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 205Interleaved 2 of 5 (I 2 of 5) — cont.2 of 5 Decoding LevelNOTEThis

Página 131 - Symbologies

Symbologies206 QuickScanTM QD2100Interleaved 2 of 5 (I 2 of 5) — cont.2 of 5 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODE2 of 5 Decoding Level =

Página 132 - Disable All Symbologies

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 207Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Length ControlThis fe

Página 133 - Coupon Control

Symbologies208 QuickScanTM QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Set Length 1This feature specifies one of the bar code lengths for I 2

Página 134 - UPC-A Enable/Disable

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 209Interleaved 2 of 5 (I 2 of 5) — cont.Datalogic 2 of 5 Set Length 1

Página 135 - UPC-A — cont

Interfaces12 QuickScanTM QD2100Table 1. Available InterfacesRS-232FEATURESRS-232 standard interfaceSelect RS232-STDSet RS-232 InterfaceFeaturesstartin

Página 136

Symbologies210 QuickScanTM QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Set Length 2This feature specifies one of the bar code lengths for I 2

Página 137 - UPC-E Enable/Disable

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 211Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Set Length 2 — cont.E

Página 138 - UPC-E — cont

Symbologies212 QuickScanTM QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Character CorrelationWhen correlation is enabled, the bar code reader w

Página 139

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 213Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 StitchingThis option

Página 140

Symbologies214 QuickScanTM QD2100Interleaved 2 of 5 CIP HRThe following options apply to the Interleaved 2 of 5 CIP HR symbology.Interleaved 2 of 5 CI

Página 141 - GTIN Formatting

Datalogic 2 of 5Product Reference Guide 215Datalogic 2 of 5 — cont.Datalogic 2 of 5 Check Character CalculationThis option

Página 142 - EAN 13 Enable/Disable

Symbologies216 QuickScanTM QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 Minimum ReadsThis feature specifies the minimum number of consecutive times

Página 143 - EAN 13 — cont

Datalogic 2 of 5Product Reference Guide 217Datalogic 2 of 5 — cont.Datalogic 2 of 5 Length ControlThis feature specifies ei

Página 144 - ISSN Enable/Disable

Symbologies218 QuickScanTM QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 1This feature specifies one of the bar code lengths for Datalogic

Página 145

Datalogic 2 of 5Product Reference Guide 219Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 1 — cont.ENTER/EXIT PROGRAMM

Página 146 - EAN 8 Enable/Disable

Configuring the InterfaceProduct Reference Guide 13KEYBOARDFEATURESAT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 9

Página 147 - EAN 8 — cont

Symbologies220 QuickScanTM QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 2This feature specifies one of the bar code lengths for Datalogic

Página 148

Datalogic 2 of 5Product Reference Guide 221Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 2 — cont.ENTER/EXIT PROGRAMM

Página 149 - UPC/EAN Global Settings

Symbologies222 QuickScanTM QD2100Datalogic 2 of 5 Interdigit Maximum RatioThis feature specifies the maximum ratio between intercharacter space and mo

Página 150 - 140 QuickScan

Datalogic 2 of 5 Interdigit Maximum Ratio = 6 Datalogic 2 of 5 Interdigit Maximum Ratio = 7 Datalogic 2 of 5 Interdigit Maximum Ratio = 8Datalogic 2

Página 151 - UPC/EAN Correlation

Symbologies224 QuickScanTM QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 Character CorrelationWhen correlation is enabled, the bar code reader will c

Página 152 - UPC/EAN Price Weight Check

Datalogic 2 of 5Product Reference Guide 225Datalogic 2 of 5 — cont.Datalogic 2 of 5 StitchingThis option enables/disables s

Página 153 - UPC-A Minimum Reads

Symbologies226 QuickScanTM QD2100CodabarThe following options apply to the Codabar symbology.Codabar Enable/DisableWhen disabled, the reader will not

Página 154 - Optional Add-ons

CodabarProduct Reference Guide 227Codabar — cont.Codabar Check Character CalculationEnable this option to enables/disables

Página 155 - Add-Ons — cont

Symbologies228 QuickScanTM QD2100Codabar — cont.Codabar Check Character TransmissionEnable this option to transmit the check character along with Coda

Página 156

CodabarProduct Reference Guide 229Codabar — cont.Codabar Start/Stop Character SetThis option specifies the format of transm

Página 157

Interfaces14 QuickScanTM QD2100KEYBOARD — cont.FEATURESKeyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboardSelect KBD-IBM-MSet K

Página 158

Symbologies230 QuickScanTM QD2100Codabar — cont.Codabar Start/Stop Character MatchWhen enabled, this option requires that start and stop characters ma

Página 159

CodabarProduct Reference Guide 231Codabar — cont.Codabar Quiet ZonesThis feature specifies the number of quiet zones for Co

Página 160

Symbologies232 QuickScanTM QD2100Codabar — cont.Codabar Minimum ReadsThis feature specifies the minimum number of consecutive times a Codabar label mu

Página 161

CodabarProduct Reference Guide 233Codabar — cont.Codabar Decoding LevelDecoding Levels are used to configure a bar code sym

Página 162

Symbologies234 QuickScanTM QD2100Codabar — cont.Codabar Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECodabar Decoding Level = 1Codabar Decoding Le

Página 163

CodabarProduct Reference Guide 235Codabar — cont.Codabar Length ControlThis feature specifies either variable length decodi

Página 164

Symbologies236 QuickScanTM QD2100Codabar — cont.Codabar Set Length 1This feature specifies one of the bar code lengths for Codabar Length Control. Len

Página 165 - Omnidirectional

CodabarProduct Reference Guide 237Codabar — cont.Codabar Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Codabar Leng

Página 166 - 156 QuickScan

Symbologies238 QuickScanTM QD2100Codabar — cont.Codabar Set Length 2This feature specifies one of the bar code lengths for Codabar Length Control. Len

Página 167 - Expanded

CodabarProduct Reference Guide 239Codabar — cont.Codabar Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect CodabarLengt

Página 168 - 158 QuickScan

Global Interface FeaturesProduct Reference Guide 15Global Interface FeaturesThe following interface features are configurab

Página 169

Symbologies240 QuickScanTM QD2100Codabar — cont.Codabar Interdigit RatioThis feature specifies the ratio between an intercharacter space and module fo

Página 170

CodabarProduct Reference Guide 241Codabar — cont.Codabar Interdigit Ratio — cont.ENTER/EXIT PROGRAMMING MODECodabar Interdi

Página 171 - 01 = Length 1 is 1 Character

Symbologies242 QuickScanTM QD2100Codabar — cont.Codabar Character CorrelationWhen correlation is enabled, the bar code reader will combine label data

Página 172

CodabarProduct Reference Guide 243Codabar — cont.Codabar StitchingThis option enables/disables stitching for Codabar labels

Página 173

Symbologies244 QuickScanTM QD2100ABC CodabarThe following options apply to the ABC Codabar symbology.ABC Codabar Enable/DisableEnables/Disables abilit

Página 174 - Limited

ABC CodabarProduct Reference Guide 245ABC Codabar — cont.ABC Codabar Dynamic Concatenation TimeoutSpecifies the timeout in

Página 175 - GS1 DataBarTM Limited — cont

Symbologies246 QuickScanTM QD2100ABC Codabar — cont.ABC Codabar Force ConcatenationForces labels starting or ending with D to be concatenated.ENTER/EX

Página 176 - Code 39 Enable/Disable

Code 11Product Reference Guide 247Code 11The following options apply to the Code 11 symbology.Code 11 Enable/DisableWhen di

Página 177 - Code 39 — cont

Symbologies248 QuickScanTM QD2100Code 11 — cont.Code 11 Check Character CalculationThis option enables/disables calculation and verification of option

Página 178

Code 11Product Reference Guide 249Code 11 — cont.Code 11 Check Character TransmissionThis feature enables/disables transmis

Página 179

Interfaces16 QuickScanTM QD2100USB Suspend Mode This setting enables/disables the ability of USB interfaces to enter suspend mode.ENTER/EXIT PROGRAMMI

Página 180

Symbologies250 QuickScanTM QD2100Code 11 — cont.Code 11 Minimum ReadsThis feature specifies the minimum number of consecutive times a Code 11 label mu

Página 181

Code 11Product Reference Guide 251Code 11 — cont.Code 11 Length ControlThis feature specifies either variable length decodi

Página 182

Symbologies252 QuickScanTM QD2100Code 11 — cont.Code 11 Set Length 1This feature specifies one of the bar code lengths for Code 11 Length Control. Len

Página 183

Code 11Product Reference Guide 253Code 11 — cont.Code 11 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 11 Set

Página 184

Symbologies254 QuickScanTM QD2100Code 11 — cont.Code 11 Set Length 2This feature specifies one of the bar code lengths for Code 11 Length Control. Len

Página 185

Code 11Product Reference Guide 255Code 11 — cont.Code 11 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 11 Leng

Página 186

Symbologies256 QuickScanTM QD2100Code 11 — cont.Code 11 Interdigit RatioThis feature specifies the ratio between an intercharacter space and module fo

Página 187

Code 11Product Reference Guide 257Code 11 — cont.Code 11 Interdigit Ratio — cont.ENTER/EXIT PROGRAMMING MODECode 11 Interdi

Página 188

Symbologies258 QuickScanTM QD2100Code 11 Decoding LevelDecoding Levels are used to configure a bar code symbology decoder to be very aggressive to ver

Página 189

Code 11Product Reference Guide 259Code 11 — cont.Code 11 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECodabar Decoding

Página 190

Product Reference Guide 17Chapter 4General FeaturesDouble Read TimeoutTo prevent a double read of the same label, the Double Read Timeout sets the min

Página 191

Symbologies260 QuickScanTM QD2100Code 11 — cont.Code 11 Character CorrelationWhen correlation is enabled, the bar code reader will combine label data

Página 192 - Code 39 Stitching

Code 11Product Reference Guide 261Code 11 StitchingThis option enables/disables stitching for Code 11 labels. When parts of

Página 193 - Code 32 Enable/Disable

Symbologies262 QuickScanTM QD2100Standard 2 of 5The following options apply to the Standard 2 of 5 symbology.Standard 2 of 5 Enable/DisableWhen disabl

Página 194 - 184 QuickScan

Standard 2 of 5Product Reference Guide 263Standard 2 of 5 — cont.Standard 2 of 5 Check Character CalculationThis option ena

Página 195 - Code 128

Symbologies264 QuickScanTM QD2100Standard 2 of 5 — cont.Standard 2 of 5 Minimum ReadsThis feature specifies the minimum number of consecutive times a

Página 196 - Code 128 — cont

Standard 2 of 5Product Reference Guide 265Standard 2 of 5 — cont.Standard 2 of 5 Length ControlThis feature specifies eithe

Página 197

Symbologies266 QuickScanTM QD2100Standard 2 of 5 — cont.Standard 2 of 5 Set Length 1This feature specifies one of the bar code lengths for Standard 2

Página 198

Standard 2 of 5Product Reference Guide 267Standard 2 of 5 — cont.Standard 2 of 5 Set Length 1 — cont.ENTER/EXIT PROGRAMMING

Página 199

Symbologies268 QuickScanTM QD2100Standard 2 of 5 — cont.Standard 2 of 5 Set Length 2This feature specifies one of the bar code lengths for Standard 2

Página 200

Standard 2 of 5Product Reference Guide 269Standard 2 of 5 — cont.Standard 2 of 5 Set Length 2 — cont.ENTER/EXIT PROGRAMMING

Página 201

General Features18 QuickScanTM QD2100Double Read Timeout — continuedENTER/EXIT PROGRAMMING MODEDouble Read Timeout = 0.5 SecondDouble Read Timeout = 0

Página 202

Symbologies270 QuickScanTM QD2100Standard 2 of 5 — cont.Standard 2 of 5 Character CorrelationWhen correlation is enabled, the bar code reader will com

Página 203

Standard 2 of 5Product Reference Guide 271Standard 2 of 5 StitchingThis option enables/disables stitching for Standard 2 of

Página 204

Symbologies272 QuickScanTM QD2100Industrial 2 of 5The following options apply to the Industrial 2 of 5 symbology.Industrial 2 of 5 Enable/DisableEnabl

Página 205

Industrial 2 of 5Product Reference Guide 273Industrial 2 of 5 — cont.Industrial 2 of 5 Check Character TransmissionEnables/

Página 206

Symbologies274 QuickScanTM QD2100Industrial 2 of 5 — cont.Industrial 2 of 5 Length ControlThis feature specifies either variable length decoding or fi

Página 207

Industrial 2 of 5Product Reference Guide 275Industrial 2 of 5 — cont.Industrial 2 of 5 Set Length 1This feature specifies o

Página 208

Symbologies276 QuickScanTM QD2100Industrial 2 of 5 — cont.Industrial 2 of 5 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Industrial 2 of 5 Se

Página 209

Industrial 2 of 5Product Reference Guide 277Industrial 2 of 5 — cont.Industrial 2 of 5 Set Length 2This feature specifies o

Página 210 - GS1-128 Enable

Symbologies278 QuickScanTM QD2100Industrial 2 of 5 — cont.Industrial 2 of 5 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Industrial 2 of5 Len

Página 211 - Interleaved 2 of 5 (I 2 of 5)

Industrial 2 of 5Product Reference Guide 279Industrial 2 of 5 — cont.Industrial 2 of 5 Minimum ReadsThis feature specifies

Página 212 - 202 QuickScan

Label Gone TimeoutProduct Reference Guide 19Label Gone TimeoutThis feature sets the time after the last label segment is se

Página 213

Symbologies280 QuickScanTM QD2100Industrial 2 of 5 — cont.Industrial 2 of 5 StitchingEnables/disables fixed length stitching for Industrial 2 of 5.ENT

Página 214 - I 2 of 5 Minimum Reads

IATAProduct Reference Guide 281IATAThe following options apply to the IATA symbology.IATA Enable/DisableEnables/Disables th

Página 215 - 2 of 5 Decoding Level

Symbologies282 QuickScanTM QD2100ISBT 128The following options apply to the ISBT 128 symbology.ISBT 128 ConcatenationEnables/disables ISBT128 concaten

Página 216 - 2 of 5 Decoding Level — cont

ISBT 128Product Reference Guide 283ISBT 128 Concatenation ModeSpecifies the concatenation mode between Static and Dynamic.E

Página 217 - I 2 of 5 Length Control

Symbologies284 QuickScanTM QD2100ISBT 128 — cont.ISBT 128 Dynamic Concatenation TimeoutSpecifies the timeout used by the ISBT 128 Dynamic Concatenatio

Página 218 - I 2 of 5 Set Length 1

ISBT 128Product Reference Guide 285ISBT 128 — cont.ISBT 128 Force ConcatenationWhen enabled, this feature forces all ISBT 1

Página 219 - 06 = Length 1 is 6 Characters

Symbologies286 QuickScanTM QD2100MSIThe following options apply to the MSI symbology.MSI Enable/DisableEnables/Disables ability of reader to decode MS

Página 220 - I 2 of 5 Set Length 2

MSIProduct Reference Guide 287MSI — cont.MSI Check Character CalculationEnables/Disables calculation and verification of an

Página 221 - I 2 of 5 Set Length 2 — cont

Symbologies288 QuickScanTM QD2100MSI — cont.MSI Check Character TransmissionEnables/disables transmission of an MSI check character.ENTER/EXIT PROGRAM

Página 222 - 212 QuickScan

MSIProduct Reference Guide 289MSI — cont.MSI Set Length 1This feature specifies one of the bar code lengths for MSI Length

Página 223 - I 2 of 5 Stitching

Product Reference Guide1Table of ContentsChapter 1. Introduction...

Página 224 - Datalogic 2 of 5

General Features20 QuickScanTM QD2100Label Gone Timeout — cont.ENTER/EXIT PROGRAMMING MODESelect Label Gone Timeout SettingMake a mistake? Scan the CA

Página 225 - Datalogic 2 of 5 — cont

Symbologies290 QuickScanTM QD2100MSI — cont.MSI Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect MSI Set Length 1 SettingMake a mistake? Scan the

Página 226

MSIProduct Reference Guide 291MSI — cont.MSI Set Length 2This feature specifies one of the bar code lengths for MSI Length

Página 227

Symbologies292 QuickScanTM QD2100MSI — cont.MSI Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect MSI Length 2 SettingMake a mistake? Scan the CAN

Página 228

MSIProduct Reference Guide 293MSI — cont.MSI Minimum ReadsThis feature specifies the minimum number of consecutive times an

Página 229

Symbologies294 QuickScanTM QD2100MSI — cont.MSI Decoding LevelDecoding Levels are used to configure a bar code symbology decoder to be very aggressive

Página 230

MSIProduct Reference Guide 295MSI — cont.MSI Decoding Level — cont.MSI Decoding Level = 3MSI Decoding Level = 4MSI Decoding

Página 231

Symbologies296 QuickScanTM QD2100PlesseyThe following options apply to the Plessey symbology.Plessey Enable/DisableEnables/Disables ability of reader

Página 232

PlesseyProduct Reference Guide 297Plessey — cont.Plessey Check Character CalculationEnables/Disables calculation and verifi

Página 233

Symbologies298 QuickScanTM QD2100Plessey — cont.Plessey Check Character TransmissionEnables/disables transmission of an MSI check character.ENTER/EXIT

Página 234

PlesseyProduct Reference Guide 299Plessey — cont.Plessey Set Length 1This feature specifies one of the bar code lengths for

Página 235

LED and Beeper IndicatorsProduct Reference Guide 21LED and Beeper IndicatorsPower On AlertDisables or enables the indicatio

Página 236 - Codabar Enable/Disable

Symbologies300 QuickScanTM QD2100Plessey — cont.Plessey Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Plessey Set Length 1 SettingMake a mista

Página 237 - Codabar — cont

PlesseyProduct Reference Guide 301Plessey — cont.Plessey Set Length 2This feature specifies one of the bar code lengths for

Página 238

Symbologies302 QuickScanTM QD2100Plessey — cont.Plessey Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Plessey Length 2 SettingMake a mistake?

Página 239

PlesseyProduct Reference Guide 303Plessey — cont.Plessey Minimum ReadsThis feature specifies the minimum number of consecut

Página 240

Symbologies304 QuickScanTM QD2100Plessey — cont.Plessey Decoding LevelDecoding Levels are used to configure a bar code symbology decoder to be very ag

Página 241

PlesseyProduct Reference Guide 305Plessey — cont.Plessey Decoding Level — cont.Plessey StitchingEnables/disables fixed leng

Página 242

Symbologies306 QuickScanTM QD2100Plessey — cont.Plessey Character CorrelationEnables/disables Character Correlation for Plessey.ENTER/EXIT PROGRAMMING

Página 243

Code 93Product Reference Guide 307Code 93 — cont.Code 93 Check Character CalculationEnables/disables calculation and verifi

Página 244

Symbologies308 QuickScanTM QD2100Code 93 — cont.Code 93 Check Character TransmissionEnables/disables transmission of an optional Code 93 check charact

Página 245

Code 93Product Reference Guide 309Code 93 — cont.Code 93 Set Length 1This feature specifies one of the bar code lengths for

Página 246

General Features22 QuickScanTM QD2100Good Read: When to IndicateThis feature specifies when the reader will provide indication (beep and/or flash its

Página 247

Symbologies310 QuickScanTM QD2100Code 93 — cont.Code 93 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 93 Set Length 1 SettingMake a mista

Página 248

Code 93Product Reference Guide 311Code 93 — cont.Code 93 Set Length 2This feature specifies one of the bar code lengths for

Página 249

Symbologies312 QuickScanTM QD2100Code 93 — cont.Code 93 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 93 Length 2 SettingMake a mistake?

Página 250

Code 93Product Reference Guide 313Code 93 — cont.Code 93 Minimum ReadsThis feature specifies the minimum number of consecut

Página 251

Symbologies314 QuickScanTM QD2100Code 93 — cont.Code 93 Decoding LevelDecoding Levels are used to configure a bar code symbology decoder to be very ag

Página 252

Code 93Product Reference Guide 315Code 93 — cont.Code 93 Decoding Level — cont.Code 93 Decoding Level = 3Code 93 Decoding L

Página 253

Symbologies316 QuickScanTM QD2100Code 93 — cont.Code 93 Quiet ZonesEnables/disables fixed length stitching for Code 93.ENTER/EXIT PROGRAMMING MODECode

Página 254 - ABC Codabar

Code 93Product Reference Guide 317Code 93 — cont.Code 93 StitchingDisable/enable fixed or variable length stitching for Cod

Página 255 - ABC Codabar — cont

Symbologies318 QuickScanTM QD2100Codablock FThe following options apply to the Codablock F symbology.Codablock F Enable/DisableEnables/Disables the ab

Página 256

Codablock FProduct Reference Guide 319Codablock F — cont.Codablock F EAN Enable/DisableEnables/Disables the Codablock F EAN

Página 257 - Code 11 Enable/Disable

LED and Beeper IndicatorsProduct Reference Guide 23Good Read Beep TypeSpecifies whether the good read beep has a mono or bi

Página 258 - Code 11 — cont

Symbologies320 QuickScanTM QD2100Codablock F — cont.Codablock F Length ControlThis feature specifies either variable length decoding or fixed length d

Página 259

Codablock FProduct Reference Guide 321Codablock F — cont.Codablock F Set Length 1This feature specifies one of the bar code

Página 260

Symbologies322 QuickScanTM QD2100Codablock F — cont.Codablock F Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Codablock F Length 1 SettingMake

Página 261

Codablock FProduct Reference Guide 323Codablock F — cont.Codablock F Set Length 2This feature specifies one of the bar code

Página 262

Symbologies324 QuickScanTM QD2100Codablock F — cont.Codablock F Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Codablock F Length 2 SettingMake

Página 263

Code 4Product Reference Guide 325Code 4The following options apply to the Code 4 symbology.Code 4 Enable/DisableEnables/Dis

Página 264

Symbologies326 QuickScanTM QD2100Code 4 — cont.Code 4 Check Character TransmissionThis feature enables/disables transmission of an optional Code 4 che

Página 265

Code 5Product Reference Guide 327Code 5The following options apply to the Code 5 symbology.Code 5 Enable/DisableEnables/Dis

Página 266

Symbologies328 QuickScanTM QD2100Code 5 — cont.Code 5 Check Character TransmissionThis feature enables/disables transmission of an optional Code 5 che

Página 267

Code 4 and Code 5 Common Configuration ItemsProduct Reference Guide 329Code 4 and Code 5 Common Configuration ItemsThe foll

Página 268 - Code 11 Decoding Level

General Features24 QuickScanTM QD2100Good Read Beep FrequencyAdjusts the good read beep to sound at a selectable low, medium or high frequency, se-lec

Página 269

Symbologies330 QuickScanTM QD2100Code 4 and Code 5 Common Configuration Items — cont.Code 4 and 5 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECod

Página 270

Code 4 and Code 5 Common Configuration ItemsProduct Reference Guide 331Code 4 and Code 5 Common Configuration Items — cont.

Página 271 - Code 11 Stitching

Symbologies332 QuickScanTM QD2100Follett 2 of 5The following options apply to the Follett 2 of 5 symbology.Follett 2 of 5 Enable/DisableEnables/Disabl

Página 272 - Standard 2 of 5

Product Reference Guide 333Appendix ATechnical SpecificationsTable 45 contains Physical and Performance Characteristics, User Environment and Regulato

Página 273 - Standard 2 of 5 — cont

334 QuickScanTM QD2100Decode CapabilityUPC/EAN/JAN, P2 /P5 GS1-128 add-ons; Code 39; Code 39 Full ASCII; Code 32 (Italian Pharmacode); Code 128; ISBT

Página 274

Standard Cable PinoutsProduct Reference Guide 335Standard Cable PinoutsFigure 7 and Table 46 provide standard pinout inform

Página 275

336 QuickScanTM QD2100NOTES

Página 276

Product Reference Guide 337Appendix BStandard DefaultsThe most common configuration settings are listed in the “Default” column of Table 47. The setti

Página 277

338 QuickScanTM QD2100Baud Rate960041Data Bits8 Data Bits43Stop Bits1 Stop Bit44ParityNone45Handshaking ControlDisable46RS-232/USB-COMIntercharacter D

Página 278

Product Reference Guide 33946xx Number of Host Resets686Transmit Labels in Code 39 FormatIBM Std Format89IBM 46XX Interface

Página 279

LED and Beeper IndicatorsProduct Reference Guide 25Good Read Beep Length — continuedENTER/EXIT PROGRAMMING MODEGood Read Be

Página 280

340 QuickScanTM QD2100Expand UPC-E to EAN-13Don’t Expand128Expand UPC-E to UPC-ADon’t Expand128UPC-E Number System Character TransmissionTransmit129UP

Página 281 - Standard 2 of 5 Stitching

Product Reference Guide 341GS1 DataBar OmnidirectionalGS1 DataBar Omnidirectional Enable/DisableDisable155GS1 DataBar Omnid

Página 282 - Industrial 2 of 5

342 QuickScanTM QD2100Code 39 Length ControlVariable174Code 39 Set Length 12175Code 39 Set Length 250177Code 39 Interdigit Ratio4179Code 39 Character

Página 283 - Industrial 2 of 5 — cont

Product Reference Guide 343I 2 of 5 Check Character CalculationDisable202I 2 of 5 Check Character Transmis-sionSend203I 2 o

Página 284

344 QuickScanTM QD2100Codabar Quiet ZonesAuto231Codabar Minimum Reads2232Codabar Decoding Level3233Codabar Length ControlVariable235Codabar Set Length

Página 285

Product Reference Guide 345Standard 2 of 5 Check Character Cal-culationDisable263Standard 2 of 5 Check Character Transmissi

Página 286

346 QuickScanTM QD2100ISBT 128 Advanced Concatenation OptionsDisable285MSIMSI Enable/DisableDisable286MSI Check Character CalculationEnable Mod10287MS

Página 287

Product Reference Guide 347Code 93 Minimum Reads1 Read313Code 93 Decoding LevelLevel 3314Code 93 Quiet ZonesAuto316Code 93

Página 288

348 QuickScanTM QD2100Default ExceptionsTable 47 lists standard default settings as applied to a standard RS-232 interface. Table 48 provides a listin

Página 289

Default ExceptionsProduct Reference Guide 349EAN13/P2 Label ID Character(s) AEAN13/P5 Label ID Character(s) AEAN13/GS1-128

Página 290

General Features26 QuickScanTM QD2100Good Read Beep VolumeSelects the beeper volume (loudness) upon a good read beep. There are three selectable volum

Página 291 - IATA Enable/Disable

350 QuickScanTM QD2100EAN13/P5 Label ID Character(s) MEAN13/GS1-128 Label ID Character(s) #GS1 DataBar 14 (Omnidirectional) Label ID Character(s) uGS1

Página 292 - ISBT 128

Product Reference Guide 351Appendix CLED and Beeper IndicationsThe imager’s beeper sounds and its LED illuminates to indicate various functions or er-

Página 293 - ISBT 128 Concatenation Mode

INDICATION DESCRIPTION LED BEEPERPower-up BeepThe imager is in the process of powering-up.Imager beeps four times at high-est frequency and volume upo

Página 294 - ISBT 128 — cont

Error CodesProduct Reference Guide 353Error CodesUpon startup, if the imager sounds a long tone, this means the imager has

Página 295

354 QuickScanTM QD2100NOTES

Página 296 - MSI Enable/Disable

Product Reference Guide 355Appendix DSample bar codesThe sample bar codes in this appendix are typical representations for their symbology types.

Página 297 - MSI — cont

356 QuickScanTM QD2100Sample bar codes — continuedCode 32 CodabarCode 93 Code 11

Página 298

GS1 DataBar (RSS)Product Reference Guide 357GS1 DataBar (RSS)NOTEGS1 DataBar variants must be enabled to read the bar codes

Página 299

358 QuickScanTM QD2100NOTES

Página 300

Product Reference Guide 359Appendix EKeypadUse the bar codes in this appendix to enter numbers as you would select digits/characters from a keypad.012

Página 301

LED and Beeper IndicatorsProduct Reference Guide 27Good Read LED DurationThis feature specifies the amount of time that the

Página 302

360 QuickScanTM QD21006789ABC

Página 303

Product Reference Guide 361DEF

Página 304

362 QuickScanTM QD2100NOTES

Página 305 - MSI Decoding Level — cont

Product Reference Guide 363Appendix FScancode TablesControl Character EmulationControl character emulation selects from different scancode tables as l

Página 306 - Plessey Enable/Disable

Product Reference Guide364Interface Type PC AT PS/2 or USB-KeyboardTable 49. Scancode Set When Control Character is 00 or 01Extended characters (sky

Página 307 - Plessey — cont

Product Reference Guide365Interface Type PC AT PS/2 or USB-Keyboard — cont.Table 50. Scancode Set When Control Character is 02 x0 x1 x2 x3 x4 x5 X6 x

Página 308

Product Reference Guide366Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt ModeTable 51. Scancode Set When Control Character is 00 or 01 x0 x

Página 309

Product Reference Guide367Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode — cont.Table 52. Scancode Set When Control Character is 02 x0 x

Página 310

Product Reference Guide368Digital InterfaceTable 53. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE x

Página 311

Product Reference Guide369Digital Interface — cont.Table 54. Scancode Set When Control Character is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE x

Página 312

NOTEIndicators are dimmed during sleep.General Features28 QuickScanTM QD2100Good Read LED Duration — cont.ENTER/EXIT PROGRAMMING MODESelect Good Read

Página 313

Product Reference Guide370IBM31xx 102-keyTable 55. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF

Página 314

Product Reference Guide371IBM31xx 102-key — cont.Table 56. Scancode Set When Control Character is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0

Página 315

Product Reference Guide372IBM XTTable 57. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xNULLC(S)

Página 316

Product Reference Guide373IBM XT — cont.Table 58. Scancode Set When Control Character is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xAr Ar

Página 317 - Code 93 — cont

374 QuickScanTM QD2100Microsoft Windows Codepage 1252Windows-1252 is a character encoding of the Latin alphabet, used by default in the leg-acy compon

Página 318

Product Reference Guide 375IndexBbar codesRS-232baud rate 79RS-232 parametersparity 325, 327, 330, 332barcodescancel 359numeric barcodes 359RS-232 par

Página 319

376 QuickScanTM QD2100mat 89Nnumbers lock key 71PPerformance Characteristics 333Physical Characteristics 333Pitch – Good Read, Beeper 23, 24Pitch Tole

Página 320

ASCII Character SetThe table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed

Página 321

820044214 (Rev.J) February 2014www.datalogic.com© 2008-2014 Datalogic ADC, Inc. • All rights reserved. • Datalogic and the Datalogic logo are registe

Página 322

Scanning FeaturesProduct Reference Guide 29Scanning FeaturesScan ModeSelects the scan operating mode for the reader. Select

Página 323

2QuickScanTM QD2100Introduction ...

Página 324

General Features30 QuickScanTM QD2100Scan Mode — continuedENTER/EXIT PROGRAMMING MODEScan Mode = Trigger SingleScan Mode = Trigger Hold MultipleScan M

Página 325

Scanning FeaturesProduct Reference Guide 31Stand Mode Triggered TimeoutThis feature specifies the time to remain in Trigger

Página 326

General Features32 QuickScanTM QD2100Stand Mode Triggered Timeout — continuedENTER/EXIT PROGRAMMING MODEStand Mode Triggered Timeout = 6 SecondsStand

Página 327

Scanning FeaturesProduct Reference Guide 33Scanning Active TimeThis setting specifies the amount of time that the reader st

Página 328 - Codablock F

General Features34 QuickScanTM QD2100Scanning Active Time — cont.ENTER/EXIT PROGRAMMING MODESelect Scanning Active Time SettingMake a mistake? Scan th

Página 329 - Codablock F — cont

Flash On TimeProduct Reference Guide 35Flash On TimeThis feature specifies the ON time for the indicator LED while in Flash

Página 330

General Features36 QuickScanTM QD2100Flash On Time — cont.ENTER/EXIT PROGRAMMING MODESelect Flash ON Time SettingMake a mistake? Scan the CANCEL bar c

Página 331

Flash Off TimeProduct Reference Guide 37Flash Off TimeThis feature specifies the OFF time for the indicator LED while in Fl

Página 332

General Features38 QuickScanTM QD2100Flash Off Time — cont.ENTER/EXIT PROGRAMMING MODESelect Flash OFF Time SettingMake a mistake? Scan the CANCEL bar

Página 333

Stand Mode SensitivityProduct Reference Guide 39Stand Mode SensitivitySets the sensitivity level for stand mode wakeup. Cho

Página 334

Product Reference Guide 3Chapter 11. Data Editing...

Página 335 - Code 4 Enable/Disable

General Features40 QuickScanTM QD2100Green Spot DurationSpecifies the duration of the good read pointer beam after a good read.ENTER/EXIT PROGRAMMING

Página 336 - Code 4 — cont

Product Reference Guide 41Chapter 5RS-232 ONLY InterfaceIntroductionUse the programming bar codes in this chapter if modifications to the standard RS-

Página 337 - Code 5 Enable/Disable

RS-232 ONLY Interface42 QuickScanTM QD2100Baud Rate — continuedENTER/EXIT PROGRAMMING MODEBaud Rate = 9600Baud Rate = 19,200Baud Rate = 38,400Baud Rat

Página 338 - Code 5 — cont

Data BitsProduct Reference Guide 43Data BitsThis parameter allows the reader to interface with devices requiring a 7-bit or

Página 339 - Code 4 and 5 Decoding Level

RS-232 ONLY Interface44 QuickScanTM QD2100Stop BitsThe stop bit(s) at the end of each transmitted character marks the end of transmission of one chara

Página 340 - 330 QuickScan

ParityProduct Reference Guide 45ParityThis feature specifies parity required for sending and receiving data. A parity check

Página 341

RS-232 ONLY Interface46 QuickScanTM QD2100Handshaking ControlThe data interface consists of an RS-232 port designed to operate either with or without

Página 342 - Follett 2 of 5

Product Reference Guide 47Chapter 6RS-232/USB-Com InterfacesIntroductionThe programming bar codes in this chapter allow modifications to the standard

Página 343 - Appendix A

RS-232/USB-Com Interfaces48 QuickScanTM QD2100Intercharacter DelayThis parameter specifies the intercharacter delay between the end of one character a

Página 344 - 334 QuickScan

Intercharacter DelayProduct Reference Guide 49Intercharacter Delay — cont.ENTER/EXIT PROGRAMMING MODEIntercharacter Delay =

Página 345 - Standard Cable Pinouts

4QuickScanTM QD2100GS1 DataBarTM Omnidirectional ...

Página 346 - 336 QuickScan

RS-232/USB-Com Interfaces50 QuickScanTM QD2100Beep On ASCII BELWhen this parameter is enabled, the reader issues a beep when a <BEL> character i

Página 347 - Appendix B

ACK NAK OptionsProduct Reference Guide 51ACK NAK OptionsThis enables/disables the ability of the reader to support the RS-2

Página 348 - 338 QuickScan

RS-232/USB-Com Interfaces52 QuickScanTM QD2100ACK CharacterThis setting specifies an ASCII character or hex value to be used as the ACK character. ASC

Página 349

ACK NAK OptionsProduct Reference Guide 53ACK Character — cont.ENTER/EXIT PROGRAMMING MODESelect ACK Character SettingDEFAUL

Página 350 - 340 QuickScan

RS-232/USB-Com Interfaces54 QuickScanTM QD2100NAK CharacterThis setting specifies an ASCII character or hex value to be used as the NAK character. ASC

Página 351

ACK NAK OptionsProduct Reference Guide 55NAK Character — cont.ENTER/EXIT PROGRAMMING MODESelect NAK Character SettingDEFAUL

Página 352 - 342 QuickScan

RS-232/USB-Com Interfaces56 QuickScanTM QD2100ACK NAK Timeout ValueThis option specifies the amount of time the reader waits for an ACK character from

Página 353

ACK NAK OptionsProduct Reference Guide 57ACK NAK Timeout Value — cont.ENTER/EXIT PROGRAMMING MODESelect ACK NAK Timeout Val

Página 354 - 344 QuickScan

RS-232/USB-Com Interfaces58 QuickScanTM QD2100ACK NAK Retry CountThis feature specifies the number of times the reader retries a label transmission du

Página 355

ACK NAK OptionsProduct Reference Guide 59ACK NAK Retry Count — cont.ENTER/EXIT PROGRAMMING MODESelect ACK NAK Retry Count S

Página 356 - 346 QuickScan

Product Reference Guide 5I 2 of 5 Set Length 1 ...

Página 357

RS-232/USB-Com Interfaces60 QuickScanTM QD2100ACK NAK Error HandlingThis feature specifies the method the reader uses to handle receive errors detecte

Página 358 - Default Exceptions

Indicate Transmission FailureProduct Reference Guide 61Indicate Transmission FailureThis option enables/disables the reader

Página 359

RS-232/USB-Com Interfaces62 QuickScanTM QD2100Disable CharacterSpecifies the value of the RS-232 host command used to disable the reader.ASCII charact

Página 360 - 350 QuickScan

Disable CharacterProduct Reference Guide 63Disable Character — cont.ENTER/EXIT PROGRAMMING MODESelect Disable Character Set

Página 361 - Appendix C

RS-232/USB-Com Interfaces64 QuickScanTM QD2100Enable CharacterSpecifies the value of the RS-232 host command used to enable the reader.ASCII character

Página 362 - LED and Beeper Indications

Enable CharacterProduct Reference Guide 65Enable Character — cont.ENTER/EXIT PROGRAMMING MODESelect Enable Character Settin

Página 363 - ERROR CORRECTIVE ACTION

RS-232/USB-Com Interfaces66 QuickScanTM QD2100NOTES

Página 364 - 354 QuickScan

Product Reference Guide 67Chapter 7Keyboard InterfaceIntroductionUse the programming bar codes in this chapter to select options for USB Keyboard and

Página 365 - Appendix D

Keyboard Interface68 QuickScanTM QD2100Country ModeThis feature specifies the country/language supported by the keyboard.Only the following interfaces

Página 366 - Sample bar codes — continued

Country ModeProduct Reference Guide 69Country Mode — continuedENTER/EXIT PROGRAMMING MODECountry Mode = DenmarkSupports onl

Página 367 - GS1 DataBar (RSS)

6QuickScanTM QD2100Standard 2 of 5 Stitching ...

Página 368 - 358 QuickScan

Keyboard Interface70 QuickScanTM QD2100Country Mode — continuedENTER/EXIT PROGRAMMING MODECountry Mode = PolandSupports only the interfaces listed in

Página 369 - Appendix E

Caps Lock StateProduct Reference Guide 71Caps Lock StateThis option specifies the format in which the reader sends characte

Página 370 - 360 QuickScan

Keyboard Interface72 QuickScanTM QD2100Send Control CharactersThis feature Specifies how the reader transmits ASCII control characters to the host. Re

Página 371

Wedge Quiet IntervalProduct Reference Guide 73Wedge Quiet IntervalThis option specifies the amount of time to look for keyb

Página 372 - 362 QuickScan

Keyboard Interface74 QuickScanTM QD2100Wedge Quiet Interval — cont.ENTER/EXIT PROGRAMMING MODESelect Wedge Quiet Interval SettingMake a mistake? Scan

Página 373 - Appendix F

Intercharacter DelayProduct Reference Guide 75Intercharacter DelayThis parameter specifies the intercharacter delay between

Página 374

Keyboard Interface76 QuickScanTM QD2100Intercharacter Delay — cont.ENTER/EXIT PROGRAMMING MODEIntercharacter Delay = No DelaySelect Intercharacter Del

Página 375

Intercode DelayProduct Reference Guide 77Intercode DelaySpecifies the delay between labels transmitted to the host for this

Página 376

Keyboard Interface78 QuickScanTM QD2100Intercode Delay — cont.ENTER/EXIT PROGRAMMING MODESet Intercode DelayMake a mistake? Scan the CANCEL bar code t

Página 377

USB Keyboard SpeedProduct Reference Guide 79USB Keyboard SpeedThis option specifies the USB poll rate for a USB keyboard.NO

Página 378 - Digital Interface

Product Reference Guide 7Code 4 Enable/Disable ...

Página 379 - Digital Interface — cont

Keyboard Interface80 QuickScanTM QD2100USB Keyboard Speed — continuedENTER/EXIT PROGRAMMING MODEUSB Keyboard Speed = 6msUSB Keyboard Speed = 7msUSB Ke

Página 380 - IBM31xx 102-key

Product Reference Guide 81Chapter 8USB-OEM InterfaceIntroductionFeature settings for USB interfaces differ depending upon which host type the reader w

Página 381 - IBM31xx 102-key — cont

USB-OEM Interface82 QuickScanTM QD2100USB-OEM Device UsageThe USB-OEM protocol allows for the reader to be identified as one of two different types of

Página 382

USB-OEM Interface OptionsProduct Reference Guide 83USB-OEM Interface OptionsThis setting provides for an interface specific

Página 383 - IBM XT — cont

USB-OEM Interface84 QuickScanTM QD2100NOTES

Página 384 - 374 QuickScan

Product Reference Guide 85Chapter 9IBM 46XX InterfaceIntroductionUse the bar codes in this section to configure programmable features for available IB

Página 385 - Product Reference Guide 375

IBM 46XX Interface86 QuickScanTM QD210046xx Number of Host ResetsSpecifies how many consecutive resets are processed before the reader starts a five-s

Página 386 - 376 QuickScan

ENTER/EXIT PROGRAMMING MODE46xx Number of Host Resets = 746xx Number of Host Resets = 846xx Number of Host Resets = 946xx Number of Host Resets = 1046

Página 387 - ASCII Character Set

ENTER/EXIT PROGRAMMING MODE46xx Number of Host Resets = 1346xx Number of Host Resets = 1446xx Number of Host Resets = 15IBM 46XX Interface88 QuickScan

Página 388

Transmit Labels in Code 39 FormatProduct Reference Guide 89Transmit Labels in Code 39 FormatThis feature enable/disables tr

Comentários a estes Manuais

Sem comentários