2KN FAMILY AND DS4800
4
PARAMETER COMPLETE PATH SHC PT VALUE
Deactivation Event /IO
/Out/Out0
/Deactive
21 1 0 = None
7 = Timeout
5 = Phase On
6 = Phase Off
8 = Quality Counter >=
Threshold
Alternative
Deactivation Event
/IO
/Deactive1
/Out/Out0
516 1 0 = None
5 = Phase On
6 = Phase Off
8 = Quality Counter >=
Threshold
Deactivation
Timeout (ms)
/IO
/Out/Out0
/Timeout
22 0 Range: 40 to 15000
Activate On Any
Diagnostics Error
/IO
/Out/Out0
/ActiveDiagnoErr
551 1 0 = Disable
1 = Enable
Deactivate When /IO
All Diagnostic Errors
Recovered
/Out/Out0
/DeactiveDiagnoNoErr
552 1 0 = Disable
1 = Enable
Event Counter /IO
/Out/Out0
/EventCounter
553 0 Range: 1 to 70000
Event Counter
Mode
/IO
/Out/Out0
/EventCounterMode
554 1 0 = Consecutive
1 = Not Consecutive
Quality Counter
Threshold
/IO
/Out/Out0
/QualityCounter
Threshold
5273 0 Range: 1 to 100
BUILT-IN DIGITAL OUTPUT LINES / OUTPUT 2
Use /IO
/Out/Out1
/Use_1
5317 1 1 = Local
2 = External Fieldbus
Line State /IO
/Out/Out1
/Idle
23 1 0 = Normally Open
1 = Normally Closed
Activation Event /IO
/Out/Out1
/Active
24 0 = None
1 = Complete Read
2 = Partial Read
72