2KN FAMILY AND DS4800
3
3.5 SAVE AND RESTORE COMMANDS
The 'Data Storage' programming command must have the following format:
E<space>MODE<CR><LF>
Where:
• E:
Data Storage command.
• MODE:
Data Storage mode. The possible values are:
V = Storage in temporary (volatile) memory only.
P = Storage in temporary and permanent memory.
If the programming is correct, the device updates the configuration and confirms with
the following message:
Y<space>MODE<CR><LF>
Where:
• MODE:
Data Storage mode.
WARNING
Restart of the device is now forced. If no disconnection commands are
sent within a minimum timeout of 300 ms, device will transmit the Self
Disconnection message (refer to the Paragraph 2.3)
If programming contents are wrong (i.e. a typing error in the file) or due to a
transmission error, the device replies with the following message and programming
data will not be updated in this case:
N<space>ERRCODE<CR><LF>
Where:
• ERRCODE:
Error Code (signed DEC value).
The complete Error Codes table is provided in the Paragraph 5.3.