2KN FAMILY AND DS4800
4
PARAMETER COMPLETE PATH SHC PT VALUE
Frequency (Hz) /Reading
/Oscillating
/FirstZoneContFreq
258 1 5 = 0.5
10 = 1
15 = 1.5
20 = 2
25 = 2.5
30 = 3
35 = 3.5
40 = 4
Triggered /Reading
/Oscillating
/Triggered
5028 1 0 = Disable
1 = Enable
Second Zone
Trigger
/Reading
/Oscillating
/TriggerIn
5029 1 0 = Phase
1 = Input 1
2 = Input 2
Second Zone
Trigger Level
/Reading
/Oscillating
/TriggerInLev
5031 1 0 = Active Closed
1 = Active Open
Second Zone
Oscillating Mode
/Reading
/Oscillating
/SecondZoneMode
5032 1 1 = Fixed
2 = Continuous
Second Zone
Amplitude (degrees)
/Reading
/Oscillating
/SecondZone
Amplitude
5033 1 10 = 10
15 = 15
20 = 20
25 = 25
30 = 30
35 = 35
40 = 40
Second Zone
Frequency (Hz)
/Reading
/Oscillating
/SecondZoneContFreq
5034 1 5 = 0.5
10 = 1
15 = 1.5
20 = 2
25 = 2.5
30 = 3
35 = 3.5
40 = 4
OSCILLATING MIRROR (DS4800)
Oscillating Mode /Reading
/Oscillating4K
/Mode
5360 1 1 = Fixed
2 = Continuous
42