CBX ELECTRICAL CONNECTIONS
53
4
OUTPUT CONNECTIONS USING DS2400N POWER
Power to Output
Output device Signal
Output device
Reference
Output Device
Figure 55 - Open Emitter Output Using DS2400N Power
Power to
Output device
Output device
Reference
Output Device
Output
Signal
Figure 56 - Open Collector Output Using DS2400N Power
OUTPUT CONNECTIONS USING EXTERNAL POWER
Pulled up to External
Output Device Power
Output
Signal
Output Device
Figure 57 - Open Emitter Output Using External Power
Pulled down to External
Output Device Reference
Output
Signal
Output Device
Figure 58 - Open Collector Output Using External Power
V
CE
max = 30 Vdc
40 mA continuous max.; 130 mA pulsed max.