Página 1 - Reference Manual

DS6400Reference Manual

Página 2

x GENERAL VIEW DS6400 Figure A - DS6400 Laser Safety Label Warning and Device Class LabelIdentification Label Connector Panel Display an

Página 3 - CONTENTS

DS6400 REFERENCE MANUAL 84 9 9 READING FEATURES 9.1 DS6400 FLASH™ DYNAMIC FOCUS The DS6400 has an innovative linear motor designed to control th

Página 4

READING FEATURES 85 99.1.3 Triggered Mode In Triggered mode, the focus position can be set depending on the received external input (photocell, barri

Página 5

DS6400 REFERENCE MANUAL 86 9 9.2 ADVANCED CODE RECONSTRUCTION (ACR™ 4) The traditional way of barcode reading could be called “Linear Reading”. In

Página 6 - REFERENCES

READING FEATURES 87 9The decoder will be able to read the label with a tilt angle between +  max and -  max as shown in the following figure: Conv

Página 7 - COMPLIANCE

DS6400 REFERENCE MANUAL 88 9 For correct functioning, the PackTrack™ operating mode requires a calibration just after the installation of the scanne

Página 8 - POWER SUPPLY

READING FEATURES 89 99.3.1 Auto PackTrack™ Calibration for Reading Station Using DLAPC In a Master /Slave Reading Station working in PackTrack™ or Co

Página 9 - FCC COMPLIANCE

DS6400 REFERENCE MANUAL 90 9 Auto PackTrack Parameter Descriptions By means of the software tool DLAPC, it is possible to perform the Auto PackTrac

Página 10 - GENERAL VIEW

READING FEATURES 91 9Calibration Type: XYZ calibration with Absolute X position is forced. The coordinates for the three axes are calibrated. The X co

Página 11 - Laser Beam Output Window

DS6400 REFERENCE MANUAL 92 9 Auto PackTrack Setup 1. Click on the Start button and follow the instructions given in the Auto PackTrack procedure

Página 12

READING FEATURES 93 9 NOTE If there are any nodes that show as U or L, then you should Stop the procedure and correct the problem. If the nodes respon

Página 13

xi DS6400 Figure B - DS6400 Oscillating Mirror Version Laser Safety Label1Laser Beam Output Window2 Figure C – Display and Keypad Panel

Página 14 - GUIDE TO INSTALLATION

DS6400 REFERENCE MANUAL 94 9 3. The Absolute X coordinate requires placing a barcode label centered onto the physical X position (X Offset) on the

Página 15

READING FEATURES 95 9Auto PackTrack Report The Auto PackTrack Report file can be downloaded from the Master scanner RAM by using the Tools>File tr

Página 16

DS6400 REFERENCE MANUAL 96 9 The last section summarizes the calibration status of each scanner. -------------------------------------- SCANNERS ST

Página 17 - 1 INTRODUCTION

READING FEATURES 97 91. Select the “SPY” option from the Tools menu or click on the related icon on the Genius™ toolbar to open the following dialog

Página 18 - 1.2 APPLICATIONS

DS6400 REFERENCE MANUAL 98 9 3. By selecting the “PackTrack Calibration” option a further dialog box appears allowing to start calibration: Figur

Página 19 - DS6400 - 10X - 0YY

READING FEATURES 99 97. Repeat the same procedure for Position 2 and Position 3. 8. After calibrating the 3 positions, press the “Validate Calibrati

Página 20

DS6400 REFERENCE MANUAL 100 9 9.4 PERFORMANCE The scan rate is 800 scans/sec. Refer to the diagrams in par. 9.5 for further details on the reading

Página 21 - INTRODUCTION

READING FEATURES 101 9 Minimum Code Height for ACR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 0.25 8 9 11 13

Página 22 - 1.6 KEYPAD AND DISPLAY

DS6400 REFERENCE MANUAL 102 9 9.5 READING DIAGRAMS The reading diagram given below illustrates the convention used to calculate the minimum and max

Página 23 - 1.6.2 Test Mode

READING FEATURES 103 99.5.1 DS6400 Standard Model DS6400-100-0XX Resolution: 0.20 mm/8 mils The diagram shows a global reading area, which include

Página 24 - 1.6.3 PackTrack (Auto)

xii Figure D – Connector Panel for Master/Slave Models Main/Aux. Interface 25-pin D-Sub male connector 1 Lonworks 9-pin male connector2 Lonworks

Página 25 - USING SCANNER MENU

DS6400 REFERENCE MANUAL 104 9 The curves show the minimum and maximum radial distance. 38 36 8540 (in) 1009534 (cm) 90807570656026 24 28 30 32 55

Página 26

READING FEATURES 105 9DS6400-100-0XX - Resolution: 0.25 mm/10 mils The diagram shows a global reading area, which includes all possible focus positio

Página 27 - 1.7.3 Auto PackTrack Setup

DS6400 REFERENCE MANUAL 106 9 The curves show the minimum and maximum radial distance. 42 40 9544 (in) 11010538 (cm) 100908580757030 28 32 34 36

Página 28

READING FEATURES 107 9DS6400-100-0XX - Resolution: 0.30 mm/12 mils The diagram shows a global reading area, which includes all possible focus positio

Página 29

DS6400 REFERENCE MANUAL 108 9 The curves show the minimum and maximum radial distance. 60 56 130 64 (in) 160 15052 (cm) 140120110100908036 32 40

Página 30 - 1.8 ACCESSORIES

READING FEATURES 109 9DS6400-100-0XX - Resolution: 0.38 mm/15 mils The diagram shows a global reading area, which includes all possible focus positio

Página 31

DS6400 REFERENCE MANUAL 110 9 The curves show the minimum and maximum radial distance. 60 56 130 64 (in) 160 15052 (cm) 140120110100908036 32 40

Página 32 - 2 INSTALLATION

READING FEATURES 111 9DS6400-100-0XX - Resolution: 0.50 mm/20 mils The diagram shows a global reading area, which includes all possible focus positio

Página 33 - 2.2.1 Mounting the Scanner

DS6400 REFERENCE MANUAL 112 9 The curves show the minimum and maximum radial distance. 64 60 140 68 (in) 170 160 56 (cm) 1501301201101009040 36 4

Página 34

READING FEATURES 113 99.5.2 DS6400 Oscillating Mirror Model DS6400-105-0XX - Resolution: 0.20 mm/8 mils The diagram shows a global reading area, wh

Página 35

xiii Figure F – Connector Panel for DeviceNet Models Main/Aux. Interface 26-pin D-Sub male connector 1 DeviceNet 5-pin male connector 2 Lonworks 9

Página 36

DS6400 REFERENCE MANUAL 114 9 The curves show the minimum and maximum radial distance. 36 85(in) 34 (cm) 90807570656026 24 28 30 32 5522 0 40 45

Página 37 - INSTALLATION

READING FEATURES 115 9DS6400-105-0XX - Resolution: 0.25 mm/10 mils The diagram shows a global reading area, which includes all possible focus positio

Página 38 - 2.3 POSITIONING THE SCANNER

DS6400 REFERENCE MANUAL 116 9 The curves show the minimum and maximum radial distance. 40 38 90 42 (in) 10510036 (cm) 95858075706528 26 30 32 34

Página 39 - 2.3.1 16° Skew Positioning

READING FEATURES 117 9DS6400-105-0XX - Resolution: 0.30 mm/12 mils The diagram shows a global reading area, which includes all possible focus positio

Página 40 - 2.3.2 45° Skew Positioning

DS6400 REFERENCE MANUAL 118 9 The curves show the minimum and maximum radial distance. 6056130 64(in) 160 150 52(cm) 140 120 110 100 90 80 3632 4

Página 41 - CBX ELECTRICAL CONNECTIONS

READING FEATURES 119 9DS6400-105-0XX - Resolution: 0.38 mm/15 mils The diagram shows a global reading area, which includes all possible focus positio

Página 42

DS6400 REFERENCE MANUAL 120 9 The curves show the minimum and maximum radial distance. 60 56 130 64 (in) 160 15052 (cm) 140120110100908036 32 40

Página 43 - 3.2 MAIN SERIAL INTERFACE

READING FEATURES 121 9DS6400-105-0XX - Resolution: 0.50 mm/20 mils The diagram shows a global reading area, which includes all possible focus positio

Página 44 - 3.2.1 RS232 Interface

DS6400 REFERENCE MANUAL 122 9 The curves show the minimum and maximum radial distance. 60 56 130 64 (in) 160 15052 (cm) 140120110100908036 32 40

Página 45 - Function

MAINTENANCE 123 1010 MAINTENANCE 10.1 CLEANING Clean the laser beam output window periodically for correct operation of the scanner (see Figure A).

Página 46

xiv GUIDE TO INSTALLATION POINT-TO-POINT INSTALLATION The following can be used as a checklist to verify all the necessary steps to complete ins

Página 47 - Multidrop Cable

DS6400 REFERENCE MANUAL 124 10 The ASR procedure is principally used for PackTrack™ configurations, but it restores only a part of the system parame

Página 48 - USER INTERFACE

TROUBLESHOOTING 125 1111 TROUBLESHOOTING NOTE Before contacting your local Datalogic office or Datalogic Partner or ARC, it is suggested to save th

Página 49 - 3.4 INPUTS

DS6400 REFERENCE MANUAL 126 11 TROUBLESHOOTING GUIDE Problem Suggestion On Line Mode and Serial On Line Mode: the reader does not respond correctly

Página 50 - MEP-593 PH-1 Photocell (PNP)

TROUBLESHOOTING 127 11TROUBLESHOOTING GUIDE Problem Suggestion How do I obtain my units’ serial numbers?  The device serial number is printed on a l

Página 51

DS6400 REFERENCE MANUAL 128 12 12 TECHNICAL FEATURES ELECTRICAL FEATURES Supply Voltage 15 to 30 Vdc Power Consumption 15 W typical 1.5 to 0.7

Página 52

TECHNICAL FEATURES 129 12SOFTWARE FEATURES Readable Codes Interleaved 2/5 Code 39 Standard Codabar Code 128 GS1-128 (ex EAN 128) Code 93 (standard an

Página 53 - 3.5 OUTPUTS

DS6400 REFERENCE MANUAL 130 A A ALTERNATIVE LAYOUTS POINT-TO-POINT Using a Point-to-Point layout, the data is transmitted on the Main interface a

Página 54

ALTERNATIVE LAYOUTS 131 AFieldbus Models In this case no External Trigger is used and the CBX100/CBX500 only passes power to the reader. The DS6400 F

Página 55

DS6400 REFERENCE MANUAL 132 A ID-NET™ GATEWAY The CBX800 Gateway can be used to integrate a DS6400 reader into a high speed ID-NET™ network consist

Página 56 - 3.6 USER INTERFACE - HOST

ALTERNATIVE LAYOUTS 133 APASS THROUGH When Pass Through is activated on the Auxiliary interface, the DS6400 reader can be integrated in a network con

Página 57

xv MASTER/SLAVE LONWORKS INSTALLATION The following can be used as a checklist to verify all the steps necessary to complete installation of the DS6

Página 58

DS6400 REFERENCE MANUAL 134 A 1 2 Main Serial Interface Auxiliary Serial Interface * P.S. (Presence Sensor) connected to Input 1 (External Tri

Página 59 - Earth Ground

ALTERNATIVE LAYOUTS 135 A Figure 140 – RS232 Master/Slave for DS6400 Master/Slave Models Figure 141 – RS232 Master/Slave for DS6400 Fieldbus Mod

Página 60

DS6400 REFERENCE MANUAL 136 A MULTIPLEXER The Multiplexer connection is used to integrate a DS6400 slave reader in a Multidrop network consisting o

Página 61 - DS6400

137 GLOSSARY ACR™ 4 Each version of the base has the powerful code reconstruction technology (ACR™ 4). The new fourth generation ACR™ considerably

Página 62

138 Multidrop Line A single communications circuit that interconnects many stations, each of which contains terminal devices. See RS485. PackTrack

Página 63

139 UPC Acronym for Universal Product Code. The standard barcode type for retail food packaging in the United States. Visible Laser Diode A light so

Página 64

140 INDEX A Accessories, 14 ACR™ 4, 86 Alternative Layouts, 130 Auto PackTrack Conditions and Limits, 9, 89 Parameter Descriptions, 10, 90 Report,

Página 65 - EXTERNAL TRIGGER/ENCODER

141 Point-to-Point, 130 Positioning, 22 16° Skew Positioning, 23 45° Skew Positioning, 24 Power Supply, viii, 27, 43 Profibus Connector Panel, xiii P

Página 66 - EXTERNAL DEVICE

DECLARATION OF CONFORMITY EC-009 Rev.: 5 Pag.: 1 di 1 Datalogic Automation S.r.l. Via Lavino 2

Página 67 - 4.5 OUTPUTS

www.automation.datalogic.com

Página 68

xvi 7) Send the configuration to the Master. 8) Perform the External Memory Backup Procedure for system backup purposes (see par. 10.2). For bac

Página 69 - 4.6 USER INTERFACE

INTRODUCTION 1 11 INTRODUCTION 1.1 PRODUCT DESCRIPTION The DS6400 is a high performance laser scanner in a complete range of industrial bar code re

Página 70 - 5 LONWORKS CONNECTIONS

DS6400 REFERENCE MANUAL 2 1 1.2 APPLICATIONS The DS6400 barcode reader is specifically designed for industrial applications and for all cases requi

Página 71 - 5.2 LONWORKS INTERFACE

INTRODUCTION 3 1Feature Benefit Master working as a Multiplexer on high speed Lonworks bus  Great competitiveness of the offer, since the cost of an

Página 72

Datalogic Automation Srl Via Lavino, 265 40050 - Monte S. Pietro Bologna - Italy DS6400 Reference Manual Ed.: 10/2012

Página 73 - LONWORKS CONNECTIONS

DS6400 REFERENCE MANUAL 4 1 1.4 OSCILLATING MIRROR MODELS Oscillating mirror models are used when coverage of a large reading area is required, mai

Página 74 - 6 FIELDBUS CONNECTIONS

INTRODUCTION 5 1The mirror can be deflected up to 40°. Oscillation with respect to the output window median axis is asymmetrical ( see figure below).

Página 75 - FIELDBUS CONNECTIONS

DS6400 REFERENCE MANUAL 6 1 The following example represents the selection of an angle of +10° for the bottom line and an angle of +20° for the top

Página 76

INTRODUCTION 7 11.6.1 Internal Net This submenu can be used as an alternative to configuration through Genius™, to assign the DS6400 scanner within a

Página 77 - 6.3 DEVICENET INTERFACE

DS6400 REFERENCE MANUAL 8 1 1.6.3 PackTrack (Auto) This submenu can be used to execute the Automatic PackTrack Calibration procedure for the Readin

Página 78 - 6.4 PROFIBUS INTERFACE

INTRODUCTION 9 11.7 AUTO PACKTRACK™ CALIBRATION FOR READING STATION USING SCANNER MENU 1.7.1 Auto PackTrack Conditions and Limits The Conditions a

Página 79 - 7 TYPICAL LAYOUTS

DS6400 REFERENCE MANUAL 10 1 1.7.2 Auto PackTrack Parameter Descriptions Menu Branch Default Note PackTrack Automatic Packtrack Calibration p

Página 80

INTRODUCTION 11 1Z Offset (if necessary): for packs that are elevated above the conveyor surface (for example on tilt trays), this parameter sets an o

Página 81 - TYPICAL LAYOUTS

DS6400 REFERENCE MANUAL 12 1 Figure 6 - PCT-8000 First Run After elaborating the passage of the parcel, the Master scanner again shows the status o

Página 82 - 7.1.2 Multidata Network

INTRODUCTION 13 17. At the last step in the sequence the display prompts to place a barcode label centered onto the physical X position (X Offset) on

Página 83 - 7.1.3 Fieldbus Networks

iii CONTENTS REFERENCES ...vi Reference Do

Página 84

DS6400 REFERENCE MANUAL 14 1 1.8 ACCESSORIES The following accessories are available on request for DS6400: Name Description Part Number Power Su

Página 85 - 8 SOFTWARE CONFIGURATION

INTRODUCTION 15 1 Name Description Part Number Mirrors GFC-60 90° mirror 93A201100 GFC-600 90° mirror close distance 93A201102 * Connection Boxes

Página 86 - Test Operating Mode

DS6400 REFERENCE MANUAL 16 2 2 INSTALLATION To install the system follow the given procedure: 1. Select the mounting location for DS6400; 2. Mou

Página 87 - Automatic Operating Mode

INSTALLATION 17 22.2 MECHANICAL MOUNTING 2.2.1 Mounting the Scanner The DS6400 reader can be positioned and installed in the best way possible as a

Página 88

DS6400 REFERENCE MANUAL 18 2 The following diagrams give the overall dimensions of the reader standard model, oscillating mirror model and mounting

Página 89

INSTALLATION 19 23.350.652.361.183.902.724.112.504.344.012.204.484.457.08mminch30608516.5104.563.5699911311456110.3102180 Figure 13 - DS6400 Oscillati

Página 90 - Express Network Setup

DS6400 REFERENCE MANUAL 20 2 2.2.2 Mounting the Scanner with Accessories The following accessories allow installing the DS6400 reader in the most

Página 91 - Network Wizard

INSTALLATION 21 2The FBK-6000 is a fast bracket kit allowing a quick and easy mounting of the scanner on the ST-237 bracket. First, it is necessary t

Página 92

DS6400 REFERENCE MANUAL 22 2 2.3 POSITIONING THE SCANNER The DS6400 reader is able to decode moving barcode labels at a variety of angles, however

Página 93 - SOFTWARE CONFIGURATION

INSTALLATION 23 2The Tilt angle is represented by the value T in Figure 21. Figure 21 - "Tilt" Angle 2.3.1 16° Skew Positioning The D

Página 94

iv 3.4.1 Code Verifier...37 3.5 Outpu

Página 95

DS6400 REFERENCE MANUAL 24 2 2.3.2 45° Skew Positioning The DS6400 scanner is mounted on the ST-210 90° mounting bracket (see Figure 14). By adjus

Página 96 - 8.4 PARAMETER DEFAULT VALUES

CBX ELECTRICAL CONNECTIONS 25 33 CBX ELECTRICAL CONNECTIONS Each scanner model has the following connectors: Scanner Model Connectors Master/Slav

Página 97

DS6400 REFERENCE MANUAL 26 3 The table below gives the pinout of the CBX100/500 terminal block connectors. Use this pinout when the DS6400 reader is

Página 98

CBX ELECTRICAL CONNECTIONS 27 3 NOTE To avoid electromagnetic interference when the scanner is connected to a CBX connection box, verify the jumper p

Página 99

DS6400 REFERENCE MANUAL 28 3 3.2.1 RS232 Interface The main serial interface is used in this case for point-to-point connections; it handles commun

Página 100 - 9 READING FEATURES

CBX ELECTRICAL CONNECTIONS 29 33.2.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled communicat

Página 101 - 9.1.4 D-FLASH™ Mode

DS6400 REFERENCE MANUAL 30 3 3.2.3 RS485 Half-Duplex Interface NOTE This interface is provided for backward compatibility. We recommend using the

Página 102 - DS6400 REFERENCE MANUAL

CBX ELECTRICAL CONNECTIONS 31 3#1#0(up to 31)ScannerScannerScannerSlaveSlaveSlaveMain InterfaceRS232/RS485HOSTMultidrop GNDShieldMultidrop -Multidrop

Página 103 - 9.3 PACKTRACK™

DS6400 REFERENCE MANUAL 32 3 3.3 AUXILIARY RS232 INTERFACE The auxiliary serial interface is used exclusively for RS232 point-to-point connections

Página 104 - PackTrack™ Reference System

CBX ELECTRICAL CONNECTIONS 33 33.4 INPUTS There are four optocoupled polarity insensitive inputs available on the scanner: Input 1 (External Trigger/

Página 105 - READING FEATURES

v 9.4.1 Reading Conditions ...100 9.5 Reading Diagra

Página 106

DS6400 REFERENCE MANUAL 34 3 The driving logic of the input signals may be powered, for convenience, with the voltage supply at the CBX terminal blo

Página 107

CBX ELECTRICAL CONNECTIONS 35 3INPUT 2 (ENCODER) CONNECTIONS USING DS6400 POWER (red)(whi te)OEK-1 Encoder (PNP) (black) Figure 37 - OEK-1 Encoder P

Página 108 - Auto PackTrack Setup

DS6400 REFERENCE MANUAL 36 3 NOTE Terminal pins I34B are common to both inputs 3 and 4 and therefore these inputs cannot be driven by opposite pol

Página 109

CBX ELECTRICAL CONNECTIONS 37 33.4.1 Code Verifier If the DS6400 is used as a Code Verifier, the verifier code can be configured in software through

Página 110

DS6400 REFERENCE MANUAL 38 3 The function of each output can be defined by the user (No Read, Right, Wrong, etc.). Refer to the Genius™ Help On Line

Página 111 - Auto PackTrack Report

CBX ELECTRICAL CONNECTIONS 39 3OUTPUT 1 and 2 CONNECTIONS USING EXTERNAL POWER Output Device Power Reference OutputSignal Output Device Figure 47 -

Página 112

DS6400 REFERENCE MANUAL 40 3 OUTPUT 3 CONNECTIONS USING EXTERNAL POWER (CBX500 Only) Output Signal External Device Power or Ground Reference Figu

Página 113

CUSTOM CABLE ELECTRICAL CONNECTIONS 41 44 CUSTOM CABLE ELECTRICAL CONNECTIONS Each scanner model has the following connectors: Scanner Model Conn

Página 114

DS6400 REFERENCE MANUAL 42 4 The details of the connector pins are indicated in the following table: 14 1 2513 10191189 26 Figure 52 - 25-pin Con

Página 115

CUSTOM CABLE ELECTRICAL CONNECTIONS 43 44.1 POWER SUPPLY The supply voltage for correct operation of the scanner must be between 15 and 30 VDC. The m

Página 116 - 9.4.1 Reading Conditions

vi REFERENCES REFERENCE DOCUMENTATION The documentation related to the DS6400 management is listed below:  CBX100/CBX500 Installation Manuals

Página 117

DS6400 REFERENCE MANUAL 44 4 4.2.1 RS232 Interface The main serial interface is used for communication with the Host computer and allows both trans

Página 118 - 9.5 READING DIAGRAMS

CUSTOM CABLE ELECTRICAL CONNECTIONS 45 44.2.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled c

Página 119 - 9.5.1 DS6400 Standard Model

DS6400 REFERENCE MANUAL 46 4 4.2.3 RS485 Half-Duplex Interface NOTE This interface is provided for backward compatibility. We recommend using the

Página 120

CUSTOM CABLE ELECTRICAL CONNECTIONS 47 4 Figure 60 – DS6400 Multidrop Connection to a Multiplexer

Página 121

DS6400 REFERENCE MANUAL 48 4 4.3 AUXILIARY INTERFACE The auxiliary serial interface is used exclusively for RS232 point-to-point connections. It is

Página 122

CUSTOM CABLE ELECTRICAL CONNECTIONS 49 4the same value which usually corresponds to 5 ms when using a photoelectric sensor, while I2 is set to 500 s

Página 123 - Position = 110 cm

DS6400 REFERENCE MANUAL 50 4 INPUT 1 - 2 CONNECTIONS USING EXTERNAL POWER E XTE RN AL TRIGGE R/E NCODER DS6400 + 5V A/BVext B/AV~ ~ + - Grou nd F

Página 124

CUSTOM CABLE ELECTRICAL CONNECTIONS 51 4INPUT 3 - 4 CONNECTIONS USING EXTERNAL POWER EXTERNAL DEVICEDS6400I3A VextGround V+ 5V ~~+ -GroundVI4A + 5V

Página 125

DS6400 REFERENCE MANUAL 52 4 Output 3 has different electrical features. It is a bi-directional solid state relay with built-in current limit protec

Página 126

CUSTOM CABLE ELECTRICAL CONNECTIONS 53 4 DS6400 USER INTERFACEVext 100 Vdc maxA/BB/A Figure 69 – Output 3 Interface The command signals are filtered

Página 127

vii COMPLIANCE ELECTRICAL SAFETY This product conforms to the applicable requirements contained in the European Standard for electrical safety EN-

Página 128

DS6400 REFERENCE MANUAL 54 5 5 LONWORKS CONNECTIONS CAUTION Do not connect an RS232 port to the 9-pin Lonworks Connector. This may damage your La

Página 129

LONWORKS CONNECTIONS 55 55.1 NETWORK TERMINATION When building a Lonworks system the network must be properly terminated by positioning the BT-6000 L

Página 130

DS6400 REFERENCE MANUAL 56 5 The following diagram represents the connection between a DS6400 working as master and a DS6400 working as a slave read

Página 131

LONWORKS CONNECTIONS 57 5The diagram below represents the termination of a DS6400 (Master/Slave model) working as master by means of the BT-6000. Ma

Página 132

DS6400 REFERENCE MANUAL 58 6 6 FIELDBUS CONNECTIONS 6.1 ETHERNET INTERFACE This connector is only available for DS6400 Ethernet models and allows

Página 133

FIELDBUS CONNECTIONS 59 66.2 ETHERNET INTERFACE (OLDER MODELS) The RJ45 connector is only available for older DS6400 Ethernet models and allows the

Página 134

DS6400 REFERENCE MANUAL 60 6 The Ethernet interface can be used for TCP/IP communication with a remote or local host computer by connecting the scan

Página 135

FIELDBUS CONNECTIONS 61 66.3 DEVICENET INTERFACE NOTE When using DeviceNet, the Main serial interface is disabled and must not be physically connect

Página 136

DS6400 REFERENCE MANUAL 62 6 6.4 PROFIBUS INTERFACE The 9-pin Profibus female connector (white) is only available in the DS6400 Profibus model and

Página 137

TYPICAL LAYOUTS 63 77 TYPICAL LAYOUTS DS6400 scanners are mainly designed to work together on a high performance Lonworks sub-network to create mult

Página 138

viii Warning labels indicating exposure to laser light and the device classification are applied onto the body of the scanner (Figure A): AVOID E

Página 139 - MAINTENANCE

DS6400 REFERENCE MANUAL 64 7 NOTE For some DS6400 Lonworks Network layouts, power is propagated through the 9-pin scanner connectors. A specific ju

Página 140

TYPICAL LAYOUTS 65 7The following image shows a system consisting of five readers (mixed 8K and 6K) where the external signals (trigger, encoder, seri

Página 141 - 11 TROUBLESHOOTING

DS6400 REFERENCE MANUAL 66 7 7.1.2 Multidata Network In this layout, one master and up to 7 DS6400 slave readers have their own P.S. and therefore

Página 142

TYPICAL LAYOUTS 67 77.1.3 Fieldbus Networks The Fieldbus models (Ethernet, DeviceNet, or Profibus) offer connectivity without any converter or adapte

Página 143 - TROUBLESHOOTING

DS6400 REFERENCE MANUAL 68 7 NOTE To interface DS6400 scanners to other Host types (Fieldbus and non-Fieldbus), use the CBX800 Gateway with Host I

Página 144

SOFTWARE CONFIGURATION 69 88 SOFTWARE CONFIGURATION 8.1 GENIUS™ INSTALLATION Genius™ is a new Datalogic scanner configuration tool providing severa

Página 145 - TECHNICAL FEATURES

DS6400 REFERENCE MANUAL 70 8 After defining the parameter values the following window appears allowing to complete the reader configuration as follo

Página 146 - Main Serial Interface

SOFTWARE CONFIGURATION 71 8On Line Operating Mode Figure 92 - On Line Mode Selection This operating mode causes the reader to be connected to an ex

Página 147 - Network

DS6400 REFERENCE MANUAL 72 8 8.2.2 Genius™ Network Setup Through Master Network Setup allows configuring your Local Lonworks Network through the M

Página 148

SOFTWARE CONFIGURATION 73 8The following dialog box appears asking whether to send the configuration to the Local Device or not: 2. Click the &quo

Página 149 - ALTERNATIVE LAYOUTS

ix CE COMPLIANCE Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may

Página 150

DS6400 REFERENCE MANUAL 74 8 3. Then, proceed with the network setup by using one of the icons available on the Tool Bar according to the procedure

Página 151

SOFTWARE CONFIGURATION 75 8Network Wizard Before performing this procedure, a Lonworks address must be assigned to each slave scanner. The most pract

Página 152

DS6400 REFERENCE MANUAL 76 8 2. If desired, select a slave scanner within the "Current Devices" area and click on the icon (or select the

Página 153 - GLOSSARY

SOFTWARE CONFIGURATION 77 88.2.3 Alternative Slave Address Assignment As alternatives to Network Setup through the Master, each Slave scanner can be

Página 154

DS6400 REFERENCE MANUAL 78 8 8.3.1 Genius™ Shortcuts for Network Configuration Once the Network Setup is structured in Genius and the Master is con

Página 155

SOFTWARE CONFIGURATION 79 8It is possible to Paste, Send or Load configurations simultaneously1 to a selected number of devices by clicking the relati

Página 156

DS6400 REFERENCE MANUAL 80 8 8.4 PARAMETER DEFAULT VALUES The following table contains the list of the factory default settings for the DS6400. Ge

Página 157

SOFTWARE CONFIGURATION 81 8Parameter Default Setting Reading Parameters Beam Shutter Disabled Overflow Start Ratio 5 Overflow Stop Ratio 5 Reading

Página 158 - DECLARATION OF CONFORMITY

DS6400 REFERENCE MANUAL 82 8 Parameter Default Setting Parameters Stop Bits 1 Auxiliary Serial Port Search for CBX BM100 at Device Startup Enab

Página 159

SOFTWARE CONFIGURATION 83 8Parameter Default Setting Diagnostics PackTrack Debug Message Tx Disabled (unchecked) Enable Checked Conveyor Info Not A