www.automation.datalogic.comDS1100Reference Manual

Página 2

GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessary for complete installation of the DS1100 scanner.

Página 3 - CONTENTS

GENERAL FEATURES 1 1 INTRODUCTION 1.1 PRODUCT DESCRIPTION The DS1100 scanner with decoder offers the best cost-effective solution for demanding ind

Página 4

DS1100 1 The laser beam output window is on the side of the scanner in DS1100-XXX0 models and on the upper part of the scanner in DS1100-XXX1 models,

Página 5 - REFERENCES

GENERAL FEATURES 1 DS1100 - X X X X Optical Resolution 1 = Standard Resolution 2 = High Resolution Reading Window Position 0 = Direct 1 = 90° Optic V

Página 6 - SAFETY REGULATIONS

DS1100 2 2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the DS1100 reader and all the parts supplied with the equipment are present and intact whe

Página 7 - CE COMPLIANCE

INSTALLATION 2 2.2 MECHANICAL INSTALLATION DS1100 can be installed to operate in any position. There are three screw holes (M3 x 5) on the body of th

Página 8 - FCC COMPLIANCE

DS1100 2 2.2.1 Mounting DS1100 Using the DS1100 mounting bracket you can obtain the most suitable position for the reader as shown in the figure belo

Página 9 - GENERAL VIEW

INSTALLATION 2 2.2.2 Reading Position In DS1100-XXX1 models the laser beam is emitted from the output window with a 12° (± 2) skew angle. This allo

Página 10 - GUIDE TO INSTALLATION

DS1100 2 2.3 ELECTRICAL CONNECTIONS The DS1100 cable is equipped with a 25-pin female D-sub connector for connection with the power supply and input/

Página 11 - 1 INTRODUCTION

INSTALLATION 2 2.3.1 Power Supply The following pins of the DS1100 connector are used: 13/925VSGND1CHASSISUSER INTERFACEGNDV+ (5 Vdc)DS1100 Figure 6

Página 12 - 1.2 MODEL DESCRIPTION

Datalogic Automation Srl Via S. Vitalino, 13 40012 - Lippo di Calderara di Reno Bologna - Italy DS1100 Reference Manual Ed.: 07/2008

Página 13 - DS1100 - X X X X

DS1100 2 For this interface type, the Multidrop Address must also be set via serial channel by the WinHost utility or by ESC sequences. Figure 8 show

Página 14 - 2 INSTALLATION

INSTALLATION 2 2.3.3 Auxiliary Interface - RS232 The auxiliary serial interface is used exclusively for RS232 point-to-point connections. It is also

Página 15 - 2.2 MECHANICAL INSTALLATION

DS1100 2 2.3.4 Inputs The inputs available on the connector are indicated below: Pin Name Function 18 IN1 - input 1 - 19 EXT TRIG- extern

Página 16 - 2.2.1 Mounting DS1100

INSTALLATION 2 The general purpose input IN1, in the Standard Application Program, can be used to store the code verifier (see “Store Verifier Hw” in

Página 17 - 2.2.2 Reading Position

DS1100 2 By default, OUT1 is associated with the No Read event, which activates when the code signaled by the external trigger is not decoded, and OUT

Página 18 - 2.3 ELECTRICAL CONNECTIONS

INSTALLATION 2 2.4 USER INTERFACE The following table contains the pinout for standard RS232 PC Host interface. For other user interface types, pleas

Página 19 - 2.3.1 Power Supply

DS1100 2 2.5 POSITIONING The scanner must be positioned so that the laser beam is aligned to completely intersect the codes passing in front of it. T

Página 20 - CAUTION

INSTALLATION 2 SFigure 15 - Skew Angle The Tilt angle is represented by the value T in Figure 16. Position the reader in order to minimize the Tilt

Página 21 - USER INTERFACE

DS1100 2 2.6.1 Point-to-Point In this layout data is transmitted to the Host on the RS232 Auxiliary serial interface. The Local Echo communication mo

Página 22 - 2.3.4 Inputs

INSTALLATION 2 The main and auxiliary ports are connected as shown in the following figure.  RS232 Auxiliary Serial Interface  RS485 HD Main Seria

Página 23 - 2.3.5 Outputs

CONTENTS REFERENCES ... v Conventions ...

Página 24

DS1100 2 2.6.3 Multiplexer Each scanner is connected to a Multiplexer (for example MX4000) with the RS485 half-duplex main interface.  RS485 HD Ma

Página 25 - 2.4 USER INTERFACE

READING FEATURES 3 3 READING FEATURES The number of scans performed on the code by the DS1100 and therefore the decoding capability is influenced by

Página 26 - 2.5 POSITIONING

DS1100 3 For example, the DS1100 (500 scans/sec.) for a 25 mm high code moving at 1000 mm/s, performs: [(25/1000) * 500] - 2 = 10 scans. 3.2 PICKET

Página 27 - 2.6 TYPICAL LAYOUTS

READING FEATURES 3 3.3 PERFORMANCE The DS1100 scanner is available in different versions according to the reading performance. Version Max Code Res

Página 28 - 2.6.2 RS485 Master/Slave

DS1100 3 3.4 READING DIAGRAMS The following diagrams show the reading distance for barcodes with different densities. DS1100-1XXX Standard Resoluti

Página 29 - INSTALLATION

READING FEATURES 3 DS1100-2XXX High Resolution 10212(in)01 53(in)240 102030405060708090100110120130(mm)6050403020100102030405060(mm)0.12 mm(5 mils)0.

Página 30 - 2.6.3 Multiplexer

DS1100 4 4 MAINTENANCE 4.1 CLEANING Clean the windows periodically for continued correct operation of the reader. Dust, dirt, etc. on the windows

Página 31 - 3 READING FEATURES

TROUBLESHOOTING 5 5 TROUBLESHOOTING 5.1 GENERAL GUIDELINES When wiring the device, pay careful attention to the pin number of the signals. If you

Página 32 - 3.2 PICKET-FENCE MODE

DS1100 5 TROUBLESHOOTING GUIDE Problem Suggestions Power On: the “Power On”/”Ready” LED is not lit • Is power connected? • If using a power adapter

Página 33 - 3.3.1 Raster

TROUBLESHOOTING 5 TROUBLESHOOTING GUIDE Reading: Not possible to read the target barcode (always returns No Read) • Check synchronization of reading

Página 34 - 3.4 READING DIAGRAMS

3.3.1 Raster ... 23 3.4 Reading Diagrams ...

Página 35 - DS1100-2XXX High Resolution

DS1100 6 6 TECHNICAL FEATURES DS1100-1XXX DS1100-2XXX ELECTRICAL FEATURES Power Maximum input voltage 5 Vdc ± 5% Power consumption max. 0.4 A

Página 36 - 4 MAINTENANCE

TECHNICAL FEATURES 6 SOFTWARE FEATURES READABLE CODE SYMBOLOGIES • EAN/UPC (including Add-on 2 and Add-on 5) • Code 93 • 2/5 Interleaved • Code 12

Página 37 - 5 TROUBLESHOOTING

GLOSSARY Aperture Term used on the required CDRH warning labels to describe the laser exit window. Barcode A pattern of variable-width bars and sp

Página 38

EEPROM Electrically Erasable Programmable Read-Only Memory. An on-board non-volatile memory chip. Full Duplex Simultaneous, two-way, independent tra

Página 39 - TROUBLESHOOTING

Protocol A formal set of conventions governing the formatting and relative timing of message exchange between two communicating systems. Raster The

Página 40 - 6 TECHNICAL FEATURES

Tilt Rotation around the Z axis. Used to describe the position of the barcode with respect to the laser scan line. See pars. 2.2.1 and 2.5. Trigger

Página 41 - (Note 3)

INDEX A Accessories; 3 Auxiliary Interface - RS232; 11 C CE Compliance; vii Cleaning; 26 E Electrical Connections; 8 F FCC Compliance; viii G Gener

Página 42 - GLOSSARY

DECLARATION OF CONFORMITY 08 Datalogic Automation S.r.l., Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares tha

Página 43

www.automation.datalogic.comDS1100Reference Manual

Página 44

REFERENCES CONVENTIONS This manual uses the following conventions: "User" or "Operator" refers to anyone using a DS1100. "

Página 45

SAFETY REGULATIONS LASER SAFETY The following information is provided to comply with the rules imposed by international authorities and refers to t

Página 46

LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAX. OUTPUT RADIATION 1mW EMITTED WAVE LENGTH 630-680 nm TO EN 60825-1:2001 CAUTION-CLASS 3B

Página 47

FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equ

Página 48

GENERAL VIEW DS1100 1 65432 87 Figure A Laser Beam Output WindowTX Data LEDGood Read LEDLaser On LEDExt Trig LEDPower On LEDLaser Warning an