Datalogic DX8200A-3010 Manual de Instalação Página 51

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 50
CUSTOM CABLE ELECTRICAL CONNECTIONS
35
4
Note that GND is internally connected to chassis. The cable shield is also connected to pin 1
- CHASSIS.
DX8200
A
USER INTERFACE
23/25
GND
V- (Ground)
V+ (20
30 V dc)
VS
9/13
C
HASSIS
1
Earth Ground
Cha ssis
Figure 35 – Power Supply Using the 26-pin Connector (Vdc models)
Vac models:
The supply voltage for correct operation of the scanner must be between 110 and 230 VAC.
The max. power consumption is 48 VA including startup current.
24 Vdc is generated and available on the 26-pin connector and can be used to power
external devices through a correctly jumpered CBX100/CBX500, i.e. photocell, etc. This
voltage however cannot be used to propagate power for a Lonworks network.
A security system allows the laser to activate only once the motor has reached the correct
rotational speed; consequently, the laser beam is generated after a slight delay from the
power on of the scanner.
4.2 MAIN SERIAL INTERFACE
The main serial interface is compatible with the following electrical standards:
RS232
RS485 full-duplex
RS485 half-duplex
The main interface type and the relative parameters (baud rate, data bits, etc.) can be
set using the Genius™ utility program or the Genius™ based Host Mode Programming
procedure. For more details refer to the section "Main Serial Port" in the Genius™
Help On Line.
Vista de página 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 138 139

Comentários a estes Manuais

Sem comentários