Setup Procedure Using Programming Barcodes
21
8 PARAMETER SETTING SUMMARY
The network setup through programming barcodes automatically sets
all the necessary
parameters in order to produce a consistent and correct configuration.
The following table summarizes the modified values and the related programming actions.
Programmed Code Modified Parameters
Stand Alone
Topology Role = Other
Reading System Layout/Local Device Alternative Network Setting = Alone or Id-Net
Master Synchronized
Topology Role = Master Synchronized
Operating Mode/ Operating Mode Selection = On Line *
Slave Synchronized
Topology Role = Slave Synchronized
Slave Address = xx
Operating Mode/ Operating Mode Selection = On Line *
Master Multidata Topology Role = Master Multidata
Slave Multidata
Topology Role = Slave Multidata
Slave Address = xx
Ethernet TCP/IP
DHCP Enabled
CBX Gateway>Host Interface Type = Ethernet TCP/IP
IP Addressing = DHCP
Ethernet TCP/IP
DHCP Disabled
CBX Gateway>Host Interface Type = Ethernet TCP/IP
IP Addressing = Static Assignment (uses static IP address parameters) **
* This setting only occurs if the starting Operating Mode is Continuous or Automatic
** The Factory Default static IP Address parameter settings are:
IP Address = 172.16.11.0
Subnet Mask = 255.255.0.0
Gateway Address = 172.16.0.2