Setup Procedure Using Programming Barcodes
15
6 NETWORK STATUS MONITOR LOCK – UNLOCK BARCODE
For Master
scanners with display (or connected to a CBX500 with accessory display), the
Network Status Monitor shows diagnostic messages regarding the network. It can be
enabled/disabled through two different methods:
by means of a Genius™ parameter
with a programming barcode
The programming barcode procedure uses the AutoLearn Mode as described in chapter 1.
The code below is a “toggle-code”:
if the Network Status Monitor is disabled, the programming code enables it.
if the Network Status Monitor is enabled, the programming code disables it.
Ì$+NETDISP$-GÎ
Network Status Monitor
Network Status Monitor
On the Master display the following messages are shown:
1 N e t w o r k 1 5
* * * * * - - - - - - - - - -
1 6 N e t w o r k 3 1
- - - - - - - - - - - - - - - -
Where:
*
= Device OK
-
= Device not detected at startup
?
= Device detected at startup but not responding to polling
!
= Device with diagnostic error
The DS4800 has a two-line display and so the messages alternate.