BHS AND REDS INSTALLATION MANUAL
28
4
4.3.5 PS Offset and Direction Calibration on DX8200A
PS Offset Calibration
The PS Offset must be set as the actual measured distance (in mm) between the origin of
the scanner coordinates, see the red dot below located at the center of the scanner.
Put the measured distance in the PS Offset combo box.
DX8200A Direction Calibration
The Direction parameters available for the DX8200A are: (Forward) and 180° (Reverse)
They will be set with respect to the scanner positioning, as shown in the following drawing.
0° (Forward)
180° (Reverse)