MATRIX 300™ REFERENCE MANUAL
42
3
3.2 MECHANICAL DIMENSIONS
Matrix 300™ can be installed to operate in different positions. The twelve screw holes (M4 x
5) on the body of the reader are for mechanical fixture (Figure 24).
The diagram below gives the overall dimensions of the reader and may be used for its
installation.
Refer to par. 3.3 for various mounting solutions and correct positioning and chp. 6 for FOV
vs. Reading Distance considerations.
Figure 24 - Overall Dimensions with Connector at 0°
43
[1.69]
=
20.5
[0.81]
=
8.1
[0.32]
95
[3.73]
54
[2.13]
M4 N°4
=
36
[1.42]
=
75
[2.95]
37.5
[1.48]
36
[1.42]
29.5
[1.16]
mm
in
Optical Axes
Connector block
rotates to 90° position