Datalogic QuickScan Lite QW2100 Especificações Página 51

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 324
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 50
Handshaking Control
Product Reference Guide 41
ENTER/EXIT PROGRAMMING MODE
Handshaking Control
The data interface consists of an RS-232 port designed to operate either with or without the
hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking
Control includes the following options:
RTS — RTS is asserted during transmissions. CTS is ignored.
RTS/CTS — RTS is asserted during transmissions. CTS gates transmissions.
RTS/XON/XOFF — RTS is asserted during transmissions. CTS is ignored. XON and
XOFF gate transmissions.
RTS On/CTS — RTS is always asserted. CTS gates transmissions.
RTS/CTS Scan Control — RTS is asserted during transmissions. CTS gates transmis-
sions and controls enable and disable state of reader.
$CR2HC00
Handshaking Control = RTS
$CR2HC01
Handshaking Control = RTS/CTS
$CR2HC02
Handshaking Control = RTS/XON/XOFF
$CR2HC03
Handshaking Control = RTS On/CTS
$CR2HC04
Handshaking Control = RTS/CTS Scan Control
DEFAULT
Vista de página 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 323 324

Comentários a estes Manuais

Sem comentários