Datalogic QuickScan Lite QW2100 Especificações Página 212

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 324
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 211
Symbologies
202 QuickScan
TM
Lite QW2100
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 — cont.
Standard 2 of 5 Character Correlation
When correlation is enabled, the bar code reader will combine label data from multiple scans
when decoding. Enabling correlation will help the reader read labels that have some spots and/or
voids. It may also help read labels that have damaged areas. Enabling correlation will also
increase the chances that a label will be read incorrectly.
Standard 2 of 5 Stitching
This option enables/disables stitching for Standard 2 of 5 labels. When parts of a Standard 2 of
5 bar code are presented to the reader with this feature enabled, the bar code parts will be assem-
bled by the reader’s software, and the data will be decoded if all bar code proofing requirements
are met.
$CS2CO00
Standard 2 of 5 Character Correlation = Disable
$CS2CO01
Standard 2 of 5 Character Correlation = Enable
DEFAULT
$CS2ST00
Standard 2 of 5 Stitching = Disable
$CS2ST01
Standard 2 of 5 Stitching = Enable
DEFAULT
Vista de página 211
1 2 ... 207 208 209 210 211 212 213 214 215 216 217 ... 323 324

Comentários a estes Manuais

Sem comentários