Datalogic Magellan 2200VS Guia do Utilizador Página 37

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 46
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 36
Scale Properties:
Quick Reference Guide 33
DeviceServiceVersion:
Returns 10120XXX where XXX is the minor version.
PhysicalDeviceDescription:
Returns a descriptive string depending on the interface and device type.
PhysicalDeviceName:
Returns a descriptive string depending on the interface and device type.
Device Specific Properties:
CapDisplay:
Returns TRUE.
TRUE is returned regardless of a remote display being connected to the scanner/scale or
not.
CapDisplayText:
Returns FALSE.
FALSE is returned regardless of a remote display being connected to the scanner/scale or
not.
CapPriceCalculating:
Returns FALSE.
CapStatusUpdate:
Returns TRUE.
CapTareWeight:
Returns FALSE.
CapZeroScale:
Returns TRUE.
AsyncMode:
Returns TRUE or FALSE depending on the previous SetProperty call.
MaxDisplayTextChars:
Returns 0.
MaximumWeight:
Returns 15000 in metric mode.
Returns
30000 in pound mode.
ScaleLiveWeight:
Updated if LiveWeight is enabled.
Vista de página 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 45 46

Comentários a estes Manuais

Sem comentários