Resumo do Conteúdo

Página 1 - Gryphon™

Gryphon™ GFE4400Fixed Area ImagingBar Code Scan EngineIntegration Guide

Página 2

Mounting the Scanner6 Gryphon™ GFE4400Table 1. J1 Connector Pins AssignmentThe J1 connection on the GFE4400 scan engine is a Hirose, DF13C-12P-1.25V,1

Página 3 - Table of Contents

Mounting the ScannerIntegration Guide 7USBFor USB setup, the recommended wiring is the following. A compatible USB cable is available from Datalogic,

Página 4

Mounting the Scanner8 Gryphon™ GFE4400RS-232For RS-232 serial setup, the recommended wiring is shown below. A compatible serial cable is available fro

Página 5 - Integration Guide

Mounting the ScannerIntegration Guide 9Figure 5. ConnectionscOUT1012GNDUSER INTERFACEGFE44X0Vext 14Vdc maxOutput ConnectionHRSVCC512GNDGFE44X011TRIGGE

Página 6 - Scan Engine Care

Mounting the Scanner10 Gryphon™ GFE4400User InterfaceThe User Interface connection (J2) provides the integrator a means to monitor scan engine status

Página 7 - Technical Support

Mounting the ScannerIntegration Guide 11Table 2. J2 Connector PinsThe following table outlines scan engine status assigned to each LED (with recommend

Página 8

Mounting the Scanner12 Gryphon™ GFE4400The following is an example of a possible connection scheme for the User Interface:Figure 7. Sample Connection

Página 9 - Host Interface

Mounting the ScannerIntegration Guide 13Table 3. J3 Connector Pin AssignmentThe Good Read Beep is a 2750Hz signal burst for 100ms provided by an on bo

Página 10 - 6 Gryphon™ GFE4400

Mounting the Scanner14 Gryphon™ GFE4400Integrating the Scanner to Read at the Proper DistanceWhen deciding how to mount the OEM scanner, there are man

Página 11 - Detection

Mounting the ScannerIntegration Guide 15Design of the Scanner OpeningThe design and placement of the scanner opening within a host enclosure are criti

Página 12 - 8 Gryphon™ GFE4400

Datalogic ADC, Inc.959 Terry StreetEugene, Oregon 97402USATelephone: (541) 683-5700Fax: (541) 345-7140An Unpublished Work - All rights reserved. No p

Página 13 - External Power

Mounting the Scanner16 Gryphon™ GFE4400Integrating the Scanner Behind a WindowIt is recommended to conduct scan performance testing with any window to

Página 14 - User Interface

Mounting the ScannerIntegration Guide 17ESD ProtectionThe host enclosure design must provide adequate ESD protection for the scanner. Ideally, static

Página 15

Integration Guide 18Technical Specifications* Although the scan engine can respond to this minimum pulse width for triggering, bar code decod-ing time

Página 16 - Good Read Beep Interface

Technical SpecificationsIntegration Guide 19Item DescriptionDigital Output : Open CollectorVout 14VDCVce 20 VDC maxCollector Current 40 mA continuou

Página 17 - Scanner Ventilation

Technical Specifications20 Gryphon™ GFE4400Pitch Tolerance ± 40°Skew (Yaw) Tolerance ± 40°Print Contrast Minimum 25% minimum reflectanceField of View

Página 18 - 14 Gryphon™ GFE4400

Technical SpecificationsIntegration Guide 21Decode Capability1D Bar CodesUPC/EAN/JAN (A, E, 13, 8); UPC/EAN/JAN (including P2 /P5); UPC/EAN/JAN (inclu

Página 19 - Design of the Scanner Opening

Technical Specifications22 Gryphon™ GFE4400RS-232 Electrical ConnectionsDefault configuration is RS-232: 9600, 8, N, 1, no handshaking, ACK/NAK disabl

Página 20

Technical SpecificationsIntegration Guide 23IndicatorsThe reader’s LED L2 of J2 illuminates to indicate various functions or er-rors. An optional “Gre

Página 21 - ESD Protection

Technical Specifications24 Gryphon™ GFE4400Error CodesUpon startup, if the reader’s LED2 and Green Spot are blinking alternate-ly, this means the read

Página 22 - Technical Specifications

Integration Guide 25Mechanical SpecificationsPhysical PropertiesScanner DimensionsParameter SpecificationDimensions42.0mm x 48.0mm x 28.2mm(1.65"

Página 23

Table of ContentsGryphon™ GFE4400 Integration Guide ...1Overview ...

Página 24

Mechanical Specifications26 Gryphon™ GFE4400Scanner Dimensions (continued)BOTTOM VIEWSIDE VIEW

Página 25

Mechanical SpecificationsIntegration Guide 27Clearance Required for IntegrationTOP VIEWSIDE VIEW

Página 26 - RS-232 Electrical Connections

Mechanical Specifications28 Gryphon™ GFE4400NOTES

Página 27 - Indicators

Mechanical SpecificationsIntegration Guide 29NOTES

Página 28 - Error Codes

Mechanical Specifications30 Gryphon™ GFE4400NOTES

Página 29 - Mechanical Specifications

China RoHS Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr(VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE)

Página 30 - SIDE VIEW

Datalogic ADC, Inc.959 Terry StreetEugene, OR 97402USATelephone: (541) 683-5700Fax: (541) 345-7140© 2012 Datalogic ADC, Inc. 820049414 (Rev. X2)

Página 32 - 28 Gryphon™ GFE4400

Integration Guide 1Gryphon™ GFE4400Integration GuideThis document gives instruction, mechanical details, and design consid-erations to integrate the G

Página 33 - Integration Guide 29

Gryphon™ GFE4400 Integration Guide2 Gryphon™ GFE4400GFS4400 scan module. This document is meant to give instruction, me-chanical details, and design c

Página 34 - 30 Gryphon™ GFE4400

Gryphon™ GFE4400 Integration GuideIntegration Guide 3Technical SupportDatalogic Website SupportThe Datalogic website (www.datalogic.com) is the comple

Página 35 - China RoHS

4 Gryphon™ GFE4400Mounting the ScannerThis section describes how to design the mounting for optimum scanner performance.General ConsiderationsA typica

Página 36

Mounting the ScannerIntegration Guide 5Mounting the Scanner StandaloneThe OEM scanner is not intended for use in a standalone application. This model

Comentários a estes Manuais

Sem comentários