INSTALLATION
11
2
The Pitch angle is represented by the value P in Figure 10. Position the reader in
order to minimize the Pitch angle.
Figure 10 - Pitch Angle
The Skew angle is represented by the value S in Figure 11. Position the reader to
assure about 15° for the Skew angle. This avoids the direct reflection of the laser light
emitted by the DS2200.
For the raster version, this angle refers to the most inclined or external raster line, so
that all other raster lines assure more than 15° Skew.
Figure 11 - Skew angle
The Tilt angle is represented by the value T in Figure 12. Position the reader in order
to minimize the Tilt angle.
Figure 12 - Tilt angle
P
S
T