INSTALLATION
9
2.8.2 Network Cabling
The Multidrop line is made using RJ45 connectors and a cable having the following
specifications:
twisted pair AWG 24 wires
120 impedance
maximum network cable length 1200 meters
Pin Function Multidrop Cables
1 RS485 +
2 RS485 -
3 N.C.
4 VDC
5 VDC
6 N.C.
7 VDC +
8 VDC +
5
2
RJ45
5
2
RJ45
1 1
DC-
RS485-
RS485+
Twisted Pair - RS485 bus
8
5
2
RJ45
8
5
2
RJ45
1 1
Twisted Pair - RS485 bus
Twisted Pair - Power supply
V
DC+
V
DC-
RS485
RS485
When wiring the multidrop cables, note the following:
Pin 8 (or 7) can be connected only if the power has to be propagated from a cradle to a
STARGATE™ base station or STAR-Box™ converter via the cable.
Pins 5 (or 4) should always be connected as reference ground.
To avoid excessive voltage drop, it is recommended not to propagate power between
OM-3000 cradles when used as battery chargers but to supply each cradle
individually. The total number of devices, which can be connected to a single power
supply, depends on the power supply voltage, the wire length and resistance and
therefore the voltage drop. Do NOT connect VDC+ between network devices that are
individually powered.