Datalogic AL5010 Informações Técnicas Página 57

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 56
AccuLazr™ AL5010 Product Line Manual Electrical Installation 49
Serial Communications Connections (COM1 and COM2)
The interfa
ce module provides an
RS232/RS422 terminal block for serial
point-to-point communications. Typically, network communications will use
Ethernet.
Enhanced Interface Module Basic Interface Module
Serial Communications Wiring (RS232/422)
RS232 Connections
Use RS232 for a direct connection to a controller, personal computer, or
other device. RS232 provides point-to-point communications at distances up
to 50 feet (15.2 meters). If longer cable lengths are needed, use RS422.
RS232 connections are made to the COM1 and COM2 terminal blocks.
Follow the SERIAL COM / RS232 wiring table to assure proper wiring.
04-AL5010_Electrical_Installation_R20.doc Accu-Sort Systems, Inc.
Vista de página 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 239 240

Comentários a estes Manuais

Sem comentários