AccuLazr™ AL5010 Product Line Manual Appendix D: Networking Guide 197
AL5010:C Configuration Data
This data is not used.
AL5010:I Input Data
Tag Name Value Description
AL5010:I.Data[0] Discrete Input Word See bit definitions.
AL5010:I.Data[1] Bar Code Sequence Number This field is updated every time the bar code
data is updated. However, the bar code data
will only be updated when the “Last Bar Code
Sequence Number” (see Output Data) is set
equal to this value.
AL5010:I.Data[2] Bar Code Status Not currently used.
AL5010:I.Data[3] Bar Code Size (words) Number of words which contain the bar code
data
AL5010:I.Data[4-67] Bar Code Data
Discrete Input Word
Bit
0 AL5010 Programmable Output #1
1 AL5010 Programmable Output #2
2 AL5010 Programmable Output #3
3 AL5010 Programmable Output #4
4 AL5010 Programmable Output #5
5 AL5010 Programmable Output #6
6 AL5010 Programmable Output #7
7 AL5010 Programmable Output #8
8-15 Unused
AL5010:O Output Data
Tag Name Value Description
AL5010:O.Data[0] Discrete Output Word See bit definitions.
AL5010:O.Data[1] Last Bar code Sequence
Number Received
This field must be updated to match the Bar Code
Sequence Number each time the bar code data
has been processed.
Discrete Output Word
Bit Bit = 0 Bit = 1
0* Trigger Off Trigger On
1 – 7 Unused Unused
8* AL5010 Relay #1 Off AL5010 Relay #1 On
9* AL5010 Relay #2 Off AL5010 Relay #2 On
10* AL5010 Relay #3 Off AL5010 Relay #3 On
11* AL5010 Relay #4 Off AL5010 Relay #4 On
12-15 Unused Unused
* If enabled on AL5010
A4-AL5010_Networking_Guide_R20.doc Accu-Sort Systems, Inc.