DX8200A QUICK GUIDE
11
COMMON FEATURES
C-BOX 100 Pinout for DX8200A:
The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the DX8200A
reader is connected in a network by means of the C-BOX 100:
C-BOX 100 Terminal Block Connectors
Power
1, 3, 5 VS
2, 4, 6 GND
7, 8 EARTH GROUND
20, 40 Reserved
Inputs
27 EXT TRIG A (polarity insensitive)
28 EXT TRIG B (polarity insensitive)
29 IN 2A (polarity insensitive)
30 IN 2B (polarity insensitive)
31, 33 IN 3A (polarity insensitive)
32, 34 IN 4A (polarity insensitive)
36 IN 3B/IN 4B Reference (polarity insensitive)
Outputs
21 OUT 1+
22 OUT 1-
23 OUT 2+
24 OUT 2-
25 OUT 3A (polarity insensitive)
26 OUT 3B (polarity insensitive)
Auxiliary Interface
35 TX AUX
37 RX AUX
38, 39 GND
Main Interface
RS232 RS485 Full-Duplex RS485 Half-Duplex
20 mA C.L.
(with INT-30 only)
11, 15 TX 232 TX 485+ RTX 485+
12, 16 RTS 232 TX 485- RTX 485-
17 RX 232 RX 485+
18 CTS 232 RX 485-
10, 14, 19 SGND Main Isolated SGND Main Isolated SGND Main Isolated
9, 13 RS485 Cable Shield RS485 Cable Shield