INSTALLATION
17
2
2.6 CONNECT POWER CABLE
1. Turn the RHINO™ off before attaching the power plug.
2. Connect the power cable to vehicle power (See the following section titled “Vehicle 11-
75VDC Direct Connection.”) or to an AC adapter.
3. Connect power by inserting the power plug into the power connector on the bottom of the
RHINO™.
4. Both the plug and receptacle are keyed and care must be used when connecting the
power cable. Twist the nut of the power plug clockwise until tight.
Figure 22 - Connect Power Cable to RHINO™
5. Turn the RHINO™ on.
2.7 VEHICLE 11-75 VDC DIRECT CONNECTION
CAUTION
For proper and safe installation, the input power cable must be connected
to a fused circuit on the vehicle. This fused circuit requires a 5 Amp
maximum time delay (slow blow) high interrupting rating fuse. If the supply
connection is made directly to the battery, the fuse should be installed in
the positive lead within 5 inches of the battery positive (+) terminal.
CAUTION
For installation by trained service personnel only
WARNING
Risk of ignition or explosion. Explosive gas mixture may be vented from
battery. Work only in well-ventilated area. Avoid creating arcs and sparks at
battery terminals.