Matrix 400™
QUICK REFERENCE GUIDE
Figure A
1
2
3
4
10
9
8
6
Device Class Label
Mounting Holes (4)
Lens Cover
Lens
(separate accessory)
Mounting Holes
"POWER ON" LED
Standard Serial Interface Connector
Ethernet Connector
(Ethernet Models Only)
7
HMI X-PRESS™ Interface
5
Internal Illuminator
(separate accessory)
Ethernet Connection LED
(Ethernet Models Only)
11
NOTE
This manual illustrates a Stand Alone application. For other types of installations, such as
Pass-Through, Multiplexer Layout, etc. and for a complete reader configuration using the VisiSet™
configuration program, refer to the Matrix 400™ Reference Manual available on the CD. This
manual is also downloadable from the Web at www.automation.datalogic.com/matrix400.
8
1
2
3
4
5
6
7
9
10
11
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - QUICK REFERENCE GUIDE

Matrix 400™ QUICK REFERENCE GUIDE Figure A 1 2 3 4 10986 Device Class Label Mounting Holes (4) Lens Cover Lens (separate accessory) M

Página 2 - SERVICES AND SUPPORT

MATRIX 400™ QUICK GUIDE 10 The Autolearning Wizard option is advised for rapid configuration or for new users. It allows reader configuration in a f

Página 3 - STEP 1 – ASSEMBLE THE READER

MATRIX 400™ QUICK GUIDE 11 5. If the code symbology is not enabled by default, select a Code Setting Mode choice and press the "Code Setting&q

Página 4 - STEP 2 – CONNECT THE SYSTEM

MATRIX 400™ QUICK GUIDE 12 STEP 8 – TEST MODE Use a code suitable to your application to test the reading performance of the system. Alternatively

Página 5

MATRIX 400™ QUICK GUIDE 13 ADVANCED READER CONFIGURATION For further details on advanced product configuration, refer to the complete Reference Ma

Página 6 - STEP 4 – FOCUS THE READER

MATRIX 400™ QUICK GUIDE 14 APPENDIX X-PRESS™ is the intuitive Human Machine Interface designed to improve ease of installation and maintenance. St

Página 7

MATRIX 400™ QUICK GUIDE 15 OPTICAL ACCESSORY SELECTION Refering to Figure 18 and the formula below, use the data in the following table to calculat

Página 8

MATRIX 400™ QUICK GUIDE 16 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply Voltage 10 to 30 Vdc Power Consumption 8 W max.; 5 W typical Comm

Página 9

MATRIX 400™ QUICK GUIDE 17 MECHANICAL DIMENSIONS 109 [4.29]60.5 [2.38]123.2 [4.85]41.5 [1.63]87 [3.43]18 [0.71]30.25 [1.19]Ø61 [Ø2.40] Figure 19 –

Página 10 - MATRIX 400™ QUICK GUIDE

MATRIX 400™ QUICK GUIDE 18 PATENTS This product is covered by one or more of the following patents: U.S. patents: 6,512,218 B1; 6,616,039 B1; 6,8

Página 11 - MATRIX 400™ QUICK GUIDE

MATRIX 400™ QUICK GUIDE 19 ITALIANO Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo

Página 12 - STEP 8 – TEST MODE

MATRIX 400™ QUICK GUIDE 2 UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available o

Página 13 - ALTERNATIVE LAYOUTS

MATRIX 400™ QUICK GUIDE 20 SERIAL NUMBER REFERENCES Place the replicate Matrix 400™ base, lens and illuminator serial number labels here for refer

Página 14 - APPENDIX

MATRIX 400™ QUICK GUIDE 3 STEP 1 – ASSEMBLE THE READER The first step to perform is to assemble the accessories that make up the Matrix 400™ reade

Página 15 - = 2 (d + 35 mm) tan (α

MATRIX 400™ QUICK GUIDE 4 STEP 2 – CONNECT THE SYSTEM To connect the system in a Stand Alone configuration, you need the hardware indicated in Fig

Página 16 - TECHNICAL FEATURES

MATRIX 400™ QUICK GUIDE 5 STEP 3 – MOUNT AND POSITION THE READER 1. To mount the Matrix 400™, use the mounting brackets to obtain the most suitab

Página 17 - MECHANICAL DIMENSIONS

MATRIX 400™ QUICK GUIDE 6 STEP 4 – FOCUS THE READER Matrix 400™ provides a built-in tool called Blue Diamonds™ to aid focusing the reader. The Blu

Página 18 - COMPLIANCE

MATRIX 400™ QUICK GUIDE 7 STEP 5 – CALIBRATE IMAGE DENSITY In order to function correctly to the fullest extent of its capabilities, Matrix 400™ m

Página 19

MATRIX 400™ QUICK GUIDE 8 STEP 6 – X-PRESS™ CONFIGURATION Once Matrix 400™ has calibrated image density, you can configure it for optimal code rea

Página 20 - SERIAL NUMBER REFERENCES

MATRIX 400™ QUICK GUIDE 9 STEP 7 – INSTALLING VISISET™ CONFIGURATION PROGRAM VisiSet™ is a Datalogic reader configuration tool providing several i