Datalogic Matrix 400 Manual de Instruções Página 26

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 86
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 25
MATRIX 400™ CODE QUALITY VERIFIER SOLUTION
1
4. Press the “Positioning” button. The reader continuously acquires images and gives visual
feedback in the view image window. Move the code to the center of the field of view. The
code must be aligned across the X-axis reference line at the center of the FOV. See
figure above.
Press the “Positioning” button again to stop positioning.
2
5. Select ISO-IEC 15415/15416 option and press the "System Calibration" button. The
reader flashes once acquiring the image and auto determines the best Exposure and
Gain settings. Moreover, the reader auto determines the best Image Processing and
Decoding parameters.
The System Validation Report section of the Verifier System Setup window shows the
code type results and the calibration settings.
3
18
Vista de página 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 85 86

Comentários a estes Manuais

Sem comentários