MATRIX 400™ QUICK GUIDE
12
3. Press the "Positioning" button. The reader continuously acquires images and gives visual feedback in the
view image window. Select the largest code from the chart that completely fits into the view image window.
Move the reader (or code) to center it. The code must be aligned across the X-axis reference line at the
center of the FOV. See figure below.
Press the Positioning button again to stop positioning.
4. Select a Calibration Mode choice and press the "Calibrate" button. The reader flashes once acquiring the
image and auto determines the best exposure and gain settings. If the code symbology is enabled by default,
the code will also be decoded.