CBX800 INSTALLATION MANUAL
9
PINOUT
Pinouts
Group Name Function
Vdc Power Supply Input Voltage +
GND Power Supply Input Voltage -
Input Power
Earth Protection Earth Ground
+V Power Source – External Trigger
I1A External Trigger A (polarity insensitive)
I1B External Trigger B (polarity insensitive)
External
Trigger Input
-V Power Reference – External Trigger
+V Power Source – Inputs
I2A Input 2A (polarity insensitive)
I2B Input 2B (polarity insensitive)
Generic Input
-V Power Reference – Inputs
+V Power Source – Outputs
-V Power Reference – Outputs
O1+ Output 1+
O1- Output 1-
O2+ Output 2+
Outputs
O2- Output 2-
O3A Output 3A (polarity insensitive)
O3B Output 3B (polarity insensitive)
+V Power Source – Other I/O
I3A Input 3A (polarity insensitive)
I4A Input 4A (polarity insensitive)
-V Power Reference – Other I/O
I34B Input 3B and 4B (common) (polarity insensitive)
Other I/O
I34B Input 3B and 4B (common) (polarity insensitive)
TX Auxiliary Interface TX
RX Auxiliary Interface RX
Auxiliary
Interface
(1)
SGND Auxiliary Interface Reference
REF Network Reference
ID+ ID-NET™ network +
ID-NET™
ID- ID-NET™ network -
Network
Shield Network Cable Shield
TX Data Source Aux TX
RX Data Source Aux RX
Data Source
Auxiliary
Interface
(2)
SGND Data Source Aux Reference
RS232 RS485FD RS485HD
TX TX+ RTX+
RTS TX- RTX-
RX *RX+
CTS *RX-
Data Source
Interface
SGND SGND SGND
RS232 RS485FD RS485HD
TX TX+ RTX+
RTS TX- RTX-
RX *RX+
CTS *RX-
Host Interface
SGND SGND SGND
* Do not leave floating, see Reading Device Reference Manual for connection details.
(1)
The Auxiliary Interface group is connected to the 9-pin Auxiliary connector and is used for configuring the
CBX800 parameters through Genius™, the multilanguage software tool.
(2)
The Data Source Auxiliary group is connected to the 9-pin Data Source connector and is used for configuring
Genius-compatible reading devices through Genius™, the multilanguage software tool.