Datalogic CBX500 Manual de Instalação Página 11

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 15
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 10
CBX500 INSTALLATION MANUAL
11
9-PIN READING DEVICE AUXILIARY SERIAL INTERFACE
The reading device auxiliary serial interface available on the internal CBX500 9-pin connector can be used either
for configuration or for data monitoring.
Connections can be made to a PC or Laptop using a straight through cable or a USB-RS232 converter.
The details of the connector pins are indicated in the following table:
5 1
69
Figure 9 - 9-pin D-Sub Female Connector
9-pin Connector Pinout
Pin Name Function
2 TX Auxiliary RS232
3 RX Auxiliary RS232
5 SGND Auxiliary Reference Ground
1, 4, 6, 7, 8, 9 N.C.
NETWORK BUS TERMINATION
ID-NET™
ON
OFF
Figure 10 – ID-NET™ Termination Resistance Switch
The ID-NET™ termination resistance switch enables or disables the insertion of the bus termination resistor for
ID-NET™ network applications.
CAUTION
In ID-NET™ network applications the termination resistor must be enabled ONLY on the first
and last devices of the chain. On all the other devices this resistor MUST NOT be enabled
(OFF).
Vista de página 10
1 2 ... 6 7 8 9 10 11 12 13 14 15

Comentários a estes Manuais

Sem comentários